Provisioning Using Configuration Files
VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: (0)330 088 0195 Fax: +44 (0)1245 808299
See
"Configuration File Parameter Guide" on page 100
available for each configuration file setting.

Resynchronization: configuration file checking

You can select a number of options that determine when the VSP610A checks for new
configuration files. This process of checking for configuration files is called
Resynchronization. Resynchronization options are available on the WebUI Provisioning
page, but you can also include them in a configuration file.
The resynchronization options are:
Mode—sets the VSP610A to check for a configuration file only, a firmware update
file only, or both types of file.
Never—configuration file checking is disabled
Bootup—the VSP610A checks for new configuration files when it boots up. Any
updates are applied during the boot-up process.
Remote check-sync—enables you to start a resynchronization remotely using your
hosted server's web portal. The Remote check-sync settings are available only in
the configuration file, not the WebUI.
Repeatedly, at a defined interval from 60 to 65535 minutes (45 days).

VSP610A restart

If the VSP610A needs to restart after an auto-update, the restart happens only after the
device has been idle for one minute.
To prevent users from delaying the update process (auto-updates cannot begin until the
VSP610A has been idle for one minute), or to avoid device restarts that might interfere with
incoming calls:
set the resynchronization interval to a suitable period
upload any new configuration file(s) to your provisioning server after work hours so
that the VSP610A will download the file(s) when there is no call activity.
When you update the VSP610A by importing a configuration file using the WebUI, the
device restarts immediately after applying the new settings, regardless of whether the
VSP610A is idle.