Download Print this page

Advertisement

Quick Links

ACC-MB10
200 lb
MAX
(90 kg)
ENG
1
2013-10-8 #:125-9469-1

Advertisement

loading

Summary of Contents for peerless-AV ACC-MB10

  • Page 1 ACC-MB10 200 lb (90 kg) 2013-10-8 #:125-9469-1...
  • Page 2 This page intentionally left blank. 2013-10-8 #:125-9469-1...
  • Page 3 Tools Needed for Assembly. ENG To properly tighten screws: Tighten until screw head makes contact, then tighten another 1/2 turn. Do not overtighten screws. +1/2 5/16" (8mm) 5/32" Symbols (4mm) Do not overtighten screws. 3/8" (10mm) WARNING Skip to step. Display center.
  • Page 4: Parts List

    WARNING ENG - This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is included for wood stud, solid concrete and cinder block installation. Before installing make sure the supporting surface will support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws or damage can occur and product may fail.
  • Page 5 Optional: Additional ACC-MB10 mounts sold separately 2013-10-8 #:125-9469-1...
  • Page 6 Wood stud wall. Concrete/Cinder block. 2a-1 2b-1 WARNING ENG - When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the woods studs are a minimum of 2" x 4" nominal size. When installing to more than one stud, ensure the spacing between studs is at least 16"...
  • Page 7 2a-1 Use stud finder to locate and mark stud center lines. 2a-2 Level wallplate. Mark mounting holes on stud center lines. 2013-10-8 #:125-9469-1...
  • Page 8 2a-3 2.5" (64mm) 5/32" 5/32" (4mm) (4mm) Drill mounting holes into supporting surface (2.5" (64 mm) minimum depth required). Mounting hole must center on stud. 2a-4 Level wallplate. Install using wood screws provided. Maximum 80 in. • lb (9 N.M.). 3/8"...
  • Page 9 WARNING ENG • When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compressive strength of 2000 psi. • When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifications and have a minimum nominal width of 8".
  • Page 10 2b-1 Level wallplate. Mark mounting holes. 2b-2 2.5" (64mm) 5/16" 5/16" (8mm) (8mm) Drill mounting holes into supporting surface (2.5" (64 mm) minimum depth required). Do not drill into mortar joints. 2013-10-8 #:125-9469-1...
  • Page 11 2b-3 B (2) Insert anchor thru drywall (a) flush to concrete (b). 2b-4 Level wallplate. Install using concrete anchors and wood screws provided. 3/8" (10mm) Maximum 80 in. • lb (9 N.M.). C (2) 2013-10-8 #:125-9469-1...
  • Page 12: Limited Five-Year Warranty

    ® This warranty gives specific legal rights, and you may also have other rights which vary from state to state. Peerless-AV Peerless-AV Europe Peerless-AV de Mexico 2300 White Oak Circle Unit 3 Watford Interchange, Ave de las Industrias 413 Aurora, IL 60502...