CONTENTS Direct Flex (no severe service cables) ..............2 Direct Max (includes severe service cables) ...........3 Cover Assembly ....................4 Interior Light Module (optional) ..............5 Connections Inside Nosebox ..............5 Connections Outside Nosebox ...............6 Basic Troubleshooting ..................7 No Lights on Face of the Nosebox ............7 Batteries Not Being Charged ..............9...
• Place the negative lead on the ground stud. • If there is a battery voltage reading, skip to step 7. • If no voltage is shown, proceed to step 6. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 10
Step 6: Check the 30 amp circuit breaker using a voltmeter: • Place the positive lead on the circuit breaker stud that connects to the red junction stud closest to the DC/DC converter on the plate. • Place the negative lead on the negative post of the battery.
• Battery voltage should read a minimum of 10 volts. • If there is a voltage reading, proceed to the next step. • If there is no voltage reading, skip to step 10. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 12
Step 3: Unplug the 4-pin connector from the DC/DC converter. • Place the voltmeter positive lead in pin #1 (12 v + input). • Place the negative lead in pin #3 (ground). • Read the approximate tractor voltage. • If there is a voltage reading, proceed to the next step.
Page 13
• If the voltage reads 13+, proceed to the next step. • If the voltage does not read 13+, inspect the wiring between the junction stud and the circuit breaker and repair any issues. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 14
Step 7: Next: • Place the voltmeter negative lead on the negative battery post. • Place the positive lead on the circuit breaker closest to the battery post. • The voltage should read 13+ volts. • If the voltage reads 13+, reset the circuit breaker.
Page 15
11. • If the voltage is less than 10 volts: Ǭ Confirm the source voltage is above 13.4 volts. Ǭ If yes, proceed to step 11. Ǭ If no, replace the cover assembly. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 16
Step 11: Next: • Place the voltmeter positive lead where the blue wire is connected. • Place the negative lead where the white wire is connected. • If there is a voltage reading, inspect the wiring for defects and replace if necessary. •...
• If there is a voltage reading, proceed to the next step. • If there is no voltage reading, inspect the wiring between the source and check the fuse for continuity. Replace if necessary. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 18
Step 3: Next: • Place the voltmeter positive lead on the 30 amp fuse on the module. • Place the negative lead on the gray wire stud on the cover assembly. • The voltage should read 0 or a very low voltage. •...