Cleaning

Xstream Deep/Dive/Deep EAN40 Cleaning
Make absolutely sure Hydrochloric acid is NOT poured into the ultra-sonic cleaner. It would then
destroy the ultra-sonic cleaner and the parts attempted to be cleaned.
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid* or 15% Hydrochloric acid for
about 10 minutes or clean them using an ultra sonic cleaner. Then rinse them thoroughly in fresh water and blow them dry with
air. The synthetic parts must not be treated with solvents and must only be cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for disinfectant cleaning
Xstream Deep EAN40
Xstream Deep EAN40 1st stages/regulators intended to be used with Nitrox/Enriched gas up to EAN40 should always be
cleaned using an ultra sonic cleaner. Avoid touching the cleaned components with your bare hand, use latex or lint free gloves
when handling the components.
When cleaned rinse them thoroughly in fresh water and blow them dry with air.
Store components in such a way that they don't risk getting in contact with silicone based lubricant.
24
SERviCE maNual
Inspect
1. Check O-ring sealing surfaces
1. Check O-ring sealing surfaces
1. Check O-ring sealing surfaces