6. SERviCE

6. Service
The parts that needs to be replaced during a service are described in the Spare parts & Servicekits section of this handbook.
Make sure that you have servicekits for the corresponding model and that you have all special tools required available. The tools
required are described in the Tools section of this hand book.
For instructions on how to service the regulator follow the instruction below until you reach the
"GO TO FINAL INSPECTION" text at the end of the instruction. The instructions in this handbook must
be followed in detail step by step. Negligence can cause serious injury or even death.
A service includes the following 5 steps:
1.
Complete disassembly of the first stage and second.
2.
Inspection of disassembled parts.
3.
Cleaning prior to assembly.
4.
Assembly.
5.
Final inspection and adjustment, please refer to section 7 of this handbook.

Disassembly

Do not disassemble the regulator in the clean room environment. All parts shall be taken to the
clean room environment after inspection and after the pre-cleaning process if such is needed. Otherwise
you risk to contaminate the clean room environment. New parts should be stored in it's original packing
until it is time for assembly.
To remove o-rings, ONLY use o-ring remover tool 2297. Make sure not to damage o-ring and sealing
surfaces!!

Xstream first stage

Step
Parts
All first stages
2680 Blindscrew UNF 7/16" 1 or 2 pcs
2679 Blindscrew UNF 3/8" 2, 3 or 5 pcs
1
4568 Screw M3x10 Xstream 3 pcs
2
4767-BK Cover Xstream first stage black (discontinued)
0000-140 Cover Xstream first stage chrome
3
4763 Press. spring 1.stage Xstream
4