Hitachi RAM-71QH5 Service Manual page 33

Hide thumbs Also See for RAM-71QH5:
Table of Contents

Advertisement

RAM-71QH5
Power
Power
Power
Power
Power
Power
Unit 1
Unit 2
Unit 3
Unit 4
Operation
Rush-in prevention
Power
Turns on
for heating
Outdoor fan
Compressor
rotation speed
100ms
520
480
0
520
480
0
520
480
0
520
480
0
TSKTM1, SDRCT1, SDSTEP, TSKSPT, CMAX2, PSTART and PSTARTH are EEPROM data.
All manuals and user guides at all-guides.com
1S 1S
100ms
Initialization
– 42 –
Cooling
Cooling
Cooling
Cooling
1S
Start sequence
[TSKTM1_C
]
*
Steady speed period
[SDRCT1_C
]
*
<TD control + N compensation + Diving control >
[PSTARTC3
]
*
<TD control + N compensation + Diving control >
[PSTARTC3
]
*
<TD control + N compensation + Diving control >
[PSTARTC3
]
*
<TD control + N compensation + Diving control >
[PSTARTC3
]
*
Target speed
Step up control
—1
[SDSTEP]min
/[TSKSPT] sec

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents