DOLD MINISTART GF 9016 Translation Of The Original Instructions

DOLD MINISTART GF 9016 Translation Of The Original Instructions

Softstarter and softstop device

Advertisement

Quick Links

Power Electronics
MINISTART
Softstarter And Softstop Device
GF 9016

Function Diagram

X1 / X2
L1/L2/L3
T2
kickstart
T1/T3
0,5s
M
Mot
n
t
t
0
1
t
:
start
0
t -t
ramp time
:
1
0
t -t
stop time
:
3
2
Block Diagram

Block Diagrams

1L1
3L2
5L3
supply
votlage
electronic
trigger pulse
generator
control
bridging
2T1
4T2
6T3
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
t
t
2
3
M9607_a
M9816_a
t
t
ramp control
U start
for
Translation
of the original instructions
• For soft and shockfree start of your asynchronous motors
• Less wearing and longer life for your motors and components
• Space saving and easy fitting
• Reduce load from supply mains by reducing of starting current
• According to IEC/EN 60947-4-2
• Softstart with softstop
• For motors up to 22 kW
• 2-phase control
• Adjustable start up and deceleration time als well as
starting voltage, optionally with kickstart
• Without auxiliary voltage
• W3 connection is possible
• As option current control on softstart
• Up to 15 kW: width 45 mm
Up to 22 kW: width 52.5 mm

Approvals and Markings

Applications

• Motors with gear, belt or chain drive
• Fans, pumps, conveyor systems, compresseors
• Packaging machines, door drives
• Start current limiting on 3 phase motors

Function

Softstarters are electronic devices designed to enable 1-phase or
3-phase induction motors to start smoothly. The GF 9016 slowly ramps up
the current on two phases, therefore allowing the motor torque to build up
slowly. This reduces the mechanical stress on the machine and prevents
damage to conveyed material.
When the motor is up to full speed the power semiconductors in
GF 9016 are bridged to prevent internal power losses and heat build up. In
addition GF 9016 allows a softstop function prolonging the stop time of the
motor, preventing high counter torques from abruptly stopping the motor.
t
Connection Terminals
Terminal designation
L1, L2, L3
X4
T1, T2, T3
X1+
X1
start
X2
X1
X2
boost
X3
X3
X4
X5
X5, X6
interference
X6
X7, X8
X7
bypass
X8
1
Signal description
Phase voltage L1, L2, L3
Motor voltage U, V, W
Output + 24V
Input + 24 V
at variant with wide voltage
Start / Stop
Kickstart 0,5 s
0 V
Indicator output, fault
Indicator output, device bridged
11.01.21 en / 335A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINISTART GF 9016 and is the answer not in the manual?

Questions and answers

Summary of Contents for DOLD MINISTART GF 9016

  • Page 1 Power Electronics MINISTART Translation Softstarter And Softstop Device of the original instructions GF 9016 • For soft and shockfree start of your asynchronous motors • Less wearing and longer life for your motors and components • Space saving and easy fitting •...
  • Page 2 Indication Resetting of faults LED green Power connected The fault message can be reset by disconnecting and reconnecting the LED yellow Power semiconductors bridged supply voltage. flashes with rising or falling speed at softstart - soft- stop Warning: flashes with same frequency at error (see table) LED red: On, when failure detected (only on devices ≥...
  • Page 3 Technical Data Control Input Connect conact to X1, X2 and select softstart (close contact) or softstop General Data (open contact). As option the unit can also be started by an external Temperature range: control voltage of DC 10-24 V. This has to be connected to terminals X2, Operation: 0 ...
  • Page 4 Softstart in a √3-circuit up to 22 kW Start only by connecting the mains voltage, terminals X1-X2 bridget E. Dold & Söhne GmbH & Co. KG • D-78120 Furtwangen • Bregstraße 18 • Phone +49 7723 654-0 • Fax +49 7723 654356 dold-relays@dold.com •...

Table of Contents