YOKOGAWA ISC40PR Instruction Manual

YOKOGAWA ISC40PR Instruction Manual

Retractable fitting for inductive conductivity sensor

Advertisement

Quick Links

Instruction
Manual
Model ISC40PR
Retractable fitting for
Inductive Conductivity sensor
IM 12D8K4-E-E
4th edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISC40PR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA ISC40PR

  • Page 1 Instruction Model ISC40PR Retractable fitting for Manual Inductive Conductivity sensor IM 12D8K4-E-E 4th edition...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ......................3 1-1. Description ......................3 1-2. Features .........................3 1-3. Warranty.........................3 2. SPECIFICATIONS ......................4 2-1. General........................4 2-2. Model- and suffix codes ..................5 2-3. Option codes ......................5 2-4. Sensor codes ......................5 3. INSTALLATION ......................6 3-1. Unpacking and checking ..................6 3-2.
  • Page 3: Introduction

    A safe “through the valve” insertion and claim purposes. retraction design. Yokogawa has the right to deny warranty Additional safety through a special claims after investigation of the data and designed T-bar locking mechanism.
  • Page 4: Specifications

    2. SPECIFICATIONS 2-1. General Materials Wetted parts Model ISC40PR-S (Stainless steel) Model ISC40PR-T (Titanium) - Probe Stainless steel AISI 316 Titanium (Grade 2 or 3) - O-ring seals Viton 70° shore Viton 70° shore Non-wetted parts - Stainless steel (AISI 316) and polyphenylene sulphide (PPS)
  • Page 5: Model- And Suffix Codes

    2-2. Model- and suffix codes Model Suffix Option Description Code ISC40PR Retractable Fitting, 2” BSP-female Material -S Stainless steel AISI 316 Titanium Grade 2 or 3 Probe 0.5 m length 1.0 m Adapter R2-G2 Stainless steel Adapter 2” NPT-G2 Stainless steel...
  • Page 6: Installation

    3-2. Installation site force on the probe. Take care that this The ISC40PR fitting is intended to be used force is not too large. for in-line conductivity measurement. When it is delivered with an optional ball valve or...
  • Page 7: Dimensions

    3-6. Dimensions ISO 228/1-G2 max. 345 or 845 (13.58 or 33.26) 500 or 1000 (19.70 or 39.37) min.150 (5.9) max.130 (5.11) max. 160 or 660 (6.29 or 25.98) 140 (5.51) min. 150 (5.9) max.130 (5.11) max. (NW50) 120mm or 620 (4.72 or 24.4) (NW50 (150mm or 5.9") (2") 90mm or 590...
  • Page 8: Dimensions Of The Options

    3-7. Dimensions of the options ISO 228/1-G2 ISO 7/1-R2 2 -11.5 NPT Options /A, /B, /E, /F ISO 228/1-G2 UNIVERSAL FLANGE DIN Flange DN50 PN16 ANSI Flange 2" 150 lbs JIS Flange 2" 150 lbs Options /C, /G ISO 228/1-G2 1/8-27 NPT UNIVERSAL FLANGE DIN Flange DN50 PN16...
  • Page 9: Installation Examples

    3-8. Installation examples IM 12D8K4-E-E...
  • Page 10: Mounting The Sensor Into The Fitting

    3-9. Mounting the sensor into the fitting 1. Take the sensor out of the box and 6. Hold the sensor still and turn the metal remove the cable tie carefully. tube onto the sensor. 2. Bind the separate wires of the cable Don’t rotate the cell, but rotate the together with a piece of tape.
  • Page 11: Probe Insertion

    3-10 Probe insertion 1. Position the probe for insertion. - Pushing the probe into the process needs 2. Turn the T-bar key clockwise. a force to overcome the pressure of the 3. Open the ball valve. system and the friction of the dampening 4.
  • Page 12 IM 12D8K4-E-E...
  • Page 13: Adjusting The Insertion Depth

    3-11. Adjusting the insertion depth The insertion depth of the sensor can be The maximum insertion depth is related to adjusted to your preference. the probe length mentioned in the model The insertion stop can be set for at the code of the fitting.
  • Page 14: Maintenance

    4-4. Drain port connection The ISC40PR retractable fitting can be The ISC40PR retractable fitting can be retracted from its measuring position in the equipped with optional drain port on the maintenance position by following the five flanged adapter.
  • Page 15: Exploded View

    Sensor holder SS (ISC40PR) K1500EN Outer tube 0,5 m Ti K1520UF Sensor holder Ti (ISC40PR) K1500EP Outer tube 1 m Ti K1520UJ Outer tube 0,5m SS, ISC40PR K1520UK Insertion stop K1520KF Outer tube 1,0m SS, ISC40PR K1520UL “Allan” screw K1520KC...
  • Page 16: Spare Parts List

    European website Fax (81)-422-55-1202 E-mail: info@yca.com (www.yokogawa.com/eu) E-mail: webinfo@mls.yokogawa.co.jp www.yokogawa.com/us www.yokogawa.com to contact your nearest representative. YOKOGAWA ELECTRIC ASIA Pte. Ltd. YOKOGAWA EUROPE B.V. 5 Bedok South Road Databankweg 20 Singapore 469270 3821 AL AMERSFOORT Singapore The Netherlands Tel. (65)-241-9933 Tel.