Liberty Pumps AE Series Installation And Operation Manual

Liberty Pumps AE Series Installation And Operation Manual

Single phase duplex

Advertisement

Quick Links

HAND
HAND
OFF
OFF
TM
TM
H
H
O
O
AUTO
AUTO
TM
TM
TM
A
A
g
STOP
STOP
e
TEST
TEST
c
L1 N
L1 N
ON OFF
ON OFF
OFF ON
OFF ON
POWER
POWER
3
3
L1 N
L1 N
1
L1 N
L1 N
2
L1 N
ON OFF
ON OFF
ON OFF
1
2
ON OFF
ON OFF
1
1
2
2
1
2
1
2
1 2
1
2
DUPLEX
CONTROLLER
TB1
1055156
DUPLEX
CONTROLLER
DUPLEX
DUPLEX
a
DUPLEX
CONTROLLER
CONTROLLER
TB1
1054970
CONTROLLER
DUPLEX
TB1
TB1
b
1054970
TB1
TB1
1054970
CONTROLLER
1054970
1054970
Model shown contains optional Seal Fail circuitry.
COMPONENTS
a. ON/OFF Switch - Control/Alarm Power
b. 120V Incoming Power Terminals
c. Power LED - (Green)
d. Pump HOA Switches
e. Float LEDs - (Red) x4
f. Pump LEDs
Pump Run - (Green)
Pump Fail - (Red)
PROGRAMMING INSTRUCTIONS
WITH POWER ON, HOAs OFF, FLOATS OFF OR DISCONNECTED, PRESS DESIRED FLOAT BUTTON RAPIDLY 4 TIMES AND HOLD
**PUMP LEDs WILL FLASH UPON SUCCESSFUL PROGRAMMING**
OPTIONS
FLOAT BUTTON
DEFAULT
PUMP FAIL ALARM
STOP
ON
MANUAL ALARM RESET LEAD
OFF
SEAL FAIL HORN
LAG
OFF
ALARM FLASHER
ALARM
OFF
ALARM
PUMP FAIL
SEAL FAIL
FLOAT FAIL
HIGH ALARM
Copyright © Liberty Pumps, Inc. 2019
All rights reserved.
Specifications subject to change without notice.
Phone 800-543-2550
7000 Apple Tree Avenue Bergen, NY 14416
HAND
HAND
H
H
H
H
50K
50K
f
O
O
i
1-2 ALT 2-1
1-2 ALT 2-1
25K
25K
O
O
H
H
H
H
H
H
H
H
H
H
SF1
PUMP
PUMP
PUMP
PUMP
100K
15K
15K
H
H
50K
125K
5K
5K
A
A
A
A
1-2 ALT 2-1
O
O
1
1
2
2
1-2 ALT 2-1
SEAL FAIL
SEAL FAIL
O
O
O
O
O
O
O
O
1-2 ALT 2-1
25K
150K
PUMP 1
PUMP 1
PUMP 1
PUMP 1
O
O
SF2
AUTO
AUTO
j
LEAD / LAG
15K
LEAD / LAG
A
A
LEAD / LAG
NC
5K
A
A
A
A
A
A
A
A
A
A
SELECTOR
SELECTOR
SELECTOR
SEAL FAIL
PUMP 1
PUMP 1
PUMP 1
PUMP 1
PUMP 2
PUMP 2
PUMP 2
PUMP 2
PUMP 1
PUMP 1
PUMP 1
PUMP 1
PUMP 2
PUMP 2
PUMP 1
PUMP 1
PUMP 1
PUMP 1
PUMP 2
PUMP 2
d
STOP
LEAD
LEAD
LAG
LAG
ALARM
ALARM
STOP
STOP
LEAD
LAG
ALARM
STOP
STOP
STOP
LEAD
LEAD
LAG
LAG
LAG
LAG
ALARM
ALARM
ALARM
ALARM
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
AUX
3
4
AUX
AUX
AUX
AUX
3
4
5
6
7
8
9
10
AUX
CONTACTS
AUX
AUX
4
4
5
5
6
6
7
7
8
8
9
9
10
10
3
3
3
3
4
4
4
4
5
5
6
6
7
7
8
8
9
9
10
10
6
6
7
7
8
8
9
9
10
10
10
CONTACTS
CONTACTS
3
3
4
NO C NC
CONTACTS
CONTACTS
CONTACTS
NO C NC
NO C NC
NO C NC
NO C NC
NO C NC
NO C NC
NO C NC
TB2
h
g. Simulate Float Buttons x4
h. Float Terminals x8
i. Lead/Lag Selecter Switch
j. Dual Seal Fail Pot - (Optional)
k. Dual Seal Fail LEDs - (Red) - (Optional)
l. Auxiliary Alarm Terminals
ACTIVATES IF A PUMP CAUSES "LAG" 3 CYCLES IN A ROW
LATCHES HIGH ALARM: CLEAR WITH EXTERNAL TEST SWITCH
ACTIVATES HORN UPON SEAL FAIL
FLASHES BEACON UPON HIGH ALARM
ALARM CONDITIONS
BEACON
CONTROLLER LED
HORN
FLASHING RED PUMP LIGHT
NO
FLASHING SF1, SF2
PROG
FLASHING BAD FLOAT NOT LIT NO
SOLID
ALARM FLOAT
YES
© 2019 SJE, Inc. All Rights Reserved.
SJE RHOMBUS is a trademark of SJE, INC.
Fax 585-494-1839
Email Liberty@LibertyPumps.com
SF1
SF1
100K
100K
125K
125K
150K
150K
SF1
100K
SF2
SF2
50K
125K
NC
NC
k
A Family and Employee Owned Company
25K
150K
SF2
15K
NC
5K
SEAL FAIL
l
TB2
TB2
SF1
SF1
100K
100K
Parts Included
?
Call factory with servicing questions:
PN 1038908D • Rev 08/19
7249000D P4
Copyright © Liberty Pumps, Inc. 2019
Web www.LibertyPumps.com
7000 Apple Tree Avenue Bergen, NY 14416
Single Phase Duplex
AE21L=3, AE21H=3, AE21L=4, AE21H=4
AE24L=3, AE24H=3, AE24L=4, and AE24H=4
Manufactured by SJE Rhombus
Installation and Operation Manual
This control panel must be installed and serviced by a licensed electrician in
accordance with the National Electric Code NFPA-70, state and local electrical codes.
UL Type 4X enclosures are for indoor or outdoor use.
Warranty void if panel is modified.
Liberty Pumps offers a three-year limited warranty.
For complete terms and conditions, please visit www.libertypumps.com.
1-800-543-2550
Products returned must be cleaned, sanitized, or decontaminated as necessary
prior to shipment to ensure that employees will not be exposed to health
hazards in handling said material. All applicable laws and regulations shall apply.
All rights reserved.
Specifications subject to change without notice.
Phone 800-543-2550
Fax 585-494-1839
®
Cable Weight available
separately. Order Liberty
Pumps Kit #001388
x3
or
x4
Control panel may be
ordered with or
without these items.
7249000D P1
Email Liberty@LibertyPumps.com
Web www.LibertyPumps.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Liberty Pumps AE Series

  • Page 1 FLASHING RED PUMP LIGHT SEAL FAIL FLASHING SF1, SF2 PROG FLOAT FAIL FLASHING BAD FLOAT NOT LIT NO Liberty Pumps offers a three-year limited warranty. HIGH ALARM SOLID ALARM FLOAT For complete terms and conditions, please visit www.libertypumps.com. Call factory with servicing questions:...
  • Page 2 STOP and LEAD fl oats return to their OFF positions. If the liquid level rises beyond both the STOP and LEAD fl oats to serious or fatal shock. or wet installation, we recommend a Liberty Pumps UL Connect the following wires to the proper terminal positions: Type 4X junction box.

This manual is also suitable for:

Ae21l 3Ae21h 3Ae21l 4Ae21h 4Ae24l 3Ae24h 3 ... Show all

Table of Contents