Pressgun Picco 6 Plus
LED indicators
Status / descrip‐
tion of problem
The green LED (3)
Battery charge too
flashes.
low.
Retaining bolt not
correctly closed.
Retaining bolt has
worked loose.
Green LEDs (4–6)
Displays the bat‐
tery charge
Blue LED (1)
Press machine is
flashes.
ready to connect.
Blue LED (1) illumi‐
The press
nates.
machine is con‐
nected to the app.
Red LED (2)
Press machine is
flashes.
outside the rec‐
ommended tem‐
perature range.
Red LED (2) illumi‐
Incomplete "Smart
nates.
Cycle" or device
fault.
Yellow LED (5)
The number of
flashes.
pressings per
service interval
has been reached
(40000).
Yellow LED (5) and
The press
red LED (2) illumi‐
machine has
nate.
made 42000
pressings.
The safety shut‐
down is activated.
Product information
Solution
Charge or replace the bat‐
tery.
Insert retaining bolt or check
retaining bolt and cylinder.
Insert retaining bolt or check
retaining bolt and cylinder.
NOTE!
The pressing may not have
been fully completed.
The press machine can be
connected to the app.
Bring the press machine to
the recommended tempera‐
ture range (-10°C to 50°C).
Warm up = carry out sev‐
n
eral pressings without the
press connector
Cool down = do not carry
n
out any pressings
Press the Start button. If
unsuccessful, the press
machine is defective.
Send the press machine to
your nearest service partner
for inspection and mainte‐
nance.
Send the press machine to
your nearest service partner
for inspection and mainte‐
nance.
Note: The safety shutdown
occurs after a further 2,000
pressings.
Send the press machine to
your nearest service partner
for inspection and mainte‐
nance.
16