Emerson Fisher Baumann 87000 Instruction Manual

Emerson Fisher Baumann 87000 Instruction Manual

Flexsleev sanitary control valve

Advertisement

Quick Links

Instruction Manual
D103373X012
Baumann™ 87000 Flexsleev Sanitary
Control Valve
Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. Baumann 87000 Valve
W9823
RECOMMENDED MOUNTING POSITION
FOR SELF-DRAINING

Introduction

The Baumann 87000 Flexsleev control valve (figure 1) with tri-clamp body connections and polished flow contours, is
excellent for throttling high purity liquid or gaseous media. The valve is suitable for repeated steam sterilization cycles
with 35 psi maximum steam pressures. Assembly of valve body sections uses only two bolts allowing for ease of
cleaning and inspection. A lower telltale port is provided. The valve will drain either horizontally or vertically with the
actuator in the horizontal position. The operation is not affected by vacuum.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Baumann 87000 sanitary
control valve.
Do not install, operate, or maintain Baumann 87000 control valves without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is
www.Fisher.com
1
1
2
2
. . . . . . . . . . . . . . . . . . .
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
W9824
WITH FIELDVUE™ DVC2000
DIGITAL VALVE CONTROLLER
87000 Valve
November 2011
. . . . . . . . . . . . . . . . . . . . . . .
3
4
4
5
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Fisher Baumann 87000

  • Page 1: Table Of Contents

    Instruction Manual 87000 Valve D103373X012 November 2011 Baumann™ 87000 Flexsleev Sanitary Control Valve Contents Air Piping ........Disassembly of Valve .
  • Page 2: Safety Precautions

    Do not expose this product to service conditions or variables other than those for which the product was intended. If you are not sure what these conditions are you should contact your Emerson Process Management sales office for more complete specifications.
  • Page 3: Installation And Maintenance

    Instruction Manual 87000 Valve D103373X012 November 2011 D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure on both sides of the valve. Drain the process media from both sides of the valve. D Depending on the actuator construction, it will be necessary to manage the pneumatic actuator spring pre-compression.
  • Page 4: Disassembly Of Valve

    Instruction Manual 87000 Valve November 2011 D103373X012 2. Use 6.4 mm (1/4 inch) O.D. tubing or equivalent for all air lines. If the air line exceeds 8 m (25 ft) in length, 9.5 mm (3/8 inch) tubing is preferred. For proper operation, air lines must not leak. Air pressure should not exceed 2.5 bar (35 psig).
  • Page 5: Parts Ordering

    WARNING Use only genuine Fisherr replacement parts. Components that are not supplied by Emerson Process Management should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage.
  • Page 6 Instruction Manual 87000 Valve November 2011 D103373X012 Figure 4. Upper Bonnet and Sleeve Bushing Figure 5. Upper Bonnet and Sleeve Bushing HOLE FOR ALIGNMENT PIN (KEY 15) UPPER BONNET (KEY 2) BEVELED EDGE SLEEVE BUSHING (KEY 6) TAPERED END OF SLEEVE BUSHING W9921 W9920...
  • Page 7: Mode Of Operation

    Instruction Manual 87000 Valve D103373X012 November 2011 Figure 6. Mode of Operation SHOWN 90 DEGREES OUT OF POSITION FOR CLARITY FLOW OPEN CLOSED E1296 Mode of Operation As shown in figure 6, a flexible sleeve is inserted through the length of the valve and sealed between the valve body and bonnet by O-rings.
  • Page 8: Dimensions And Weights

    Instruction Manual 87000 Valve November 2011 D103373X012 Figure 8. Dimensions (1.03) (5.8) (0.83) (0.34) FLOW (1.5) (46.25) SELF-DRAIN ANGLE 2 DEGREES (2.75) (1.05) (0.83) FLOW (0.34) (inch) E1297 RECOMMENDED MOUNTING FOR SELF-DRAINING (ACTUATOR SHOULD BE MOUNTED HORIZONTALLY) NOTE: ACTUATOR REQUIRES 115 mm (4.5 INCHES) VERTICAL CLEARANCE.
  • Page 9 Instruction Manual 87000 Valve D103373X012 November 2011 Figure 9. Dimensions (6.52) 127 (5.0) E1299 (inch) RECOMMENDED MOUNTING FOR SELF-DRAINING (ACTUATOR SHOULD BE MOUNTED HORIZONTALLY) NOTE: ACTUATOR REQUIRES 115 mm (4.5 INCHES) VERTICAL CLEARANCE.
  • Page 10 Instruction Manual 87000 Valve November 2011 D103373X012 Figure 10. Dimensions (1.03) (5.8) (40.25) (46.25) (48.06) (8.3) R228 (R9.0) (9.8) RECOMMENDED MOUNTING FOR SELF-DRAINING (ACTUATOR SHOULD BE MOUNTED HORIZONTALLY) (inch) NOTE: ACTUATOR REQUIRES 115mm (4.5 INCHES) VERTICAL CLEARANCE. E1298 Table 2. Weights, Valve, Actuator, and Positioner VALVE ACTUATOR POSITIONER...
  • Page 11 Instruction Manual 87000 Valve D103373X012 November 2011...
  • Page 12 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Baumann, Fisher, and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co.

Table of Contents