REGISTER STATUS CODING TABLE
BIT
15
Description
Not used
BIT
7
Not
Description
calibrated
WARNING: bits 13, 12, 11 and 10 are managed only in the event of hardware version DAT 100/A,
in the other hardware versions these bits are always 0.
COMMAND REGISTER CODING TABLE FOR MODBUS PROTOCOL
Register value
COMMAND REGISTER FUNCTION
0x0001
Semiautomatic zero
0x0002
Self-calibration
0x0003
Peak reset
0x0010
Calibration of the weight zero
0x0011
Calibration of the full weight scale
0x0020
Saving the data in the permanent memory
Address
Data stored in memory with command 0x0020
41001-41002 Load cells capacity
41003
Load cells sensitivity
41004
Weight division value
41101
Weight filter factor
41102
Weight stability factor
41103-41104 Auto-zero SET POINT
41105
Zero tracking factor
41106
Zero band
41107
Weight Delta
CODING DIVISION VALUE TABLE
Register
0
value
Division
0.0001 0.0002 0.0005 0.001
value
Register
9
value
Division
0.1
value
Page 32
14
13
Not used
Output 2
6
5
Wrong
Over-load
weight
1
2
3
10
11
12
0.2
0.5
1
12
11
Output 1
Input 2
4
3
Tare
Under-load
entered
4
5
0,002
0,005
0.01
13
14
2
5
10
9
Input 1
Memory Flag Not used
2
1
Stable
Zero band
weight
DATA REGISTER FUNCTION
-
-
-
-
FLOAT sample weight
-
6
7
8
0.02
0.05
15
16
17
10
20
50
8
0
Zero
center