Pavone Systems DAT 100 Technical Manual page 22

Serial and analog weighing indicator/trasnmitter
Table of Contents

Advertisement

frN-1 COM1 DATA FORMAT
It defines the data format of the RS232 serial port.
The value must be set to the same value of the PC / PLC or remote
display.
In the case of MODBUS or SLAVE protocol, selections of the 7-bit
data formats (E-7-1 and O-7-1) are not accepted (error message
"Nvalid").
Selectable Values:
N-8-1
N-8-2
E-8-1
O-8-1
E-7-1
0-7-1
Default: N-8-1
addr COM1 / COM2 SERIAL COMMUNICATION ADDRESS
Configuration of the address used in the transmission protocols and
in the MODBUS protocol.
Value from 000 to 99.
Default:01
NodE TRANSMITTED DATA WEIGHT COM1 / COM2
Selecting the value transmitted with continuous, automatic and ma-
nual protocols (see relevant paragraph).
Selectable Values:
Net
Gross
Peak
Default: Gross
dELay DELAYED RESPONSE OF THE SLAVE AND MODBUS RTU COM1
/ COM2 PROTOCOLS
Value in milliseconds, representing the delay of the instrument when
sending the response to the request of the master.
Values: from 0 to 999
Default: 000
Page 20
Select Value
Select Value
Enter Value
Select Value
Enter Value
▲ ▼
Select Value
Select Value
Select Value
▲ ▼