Error Messages And The Use Of The - RaycoWylie i3500 Calibration Instructions Manual

Rated capacity indicator system for telescopic cranes pressure sensing, multipoint version
Hide thumbs Also See for i3500:
Table of Contents

Advertisement

Slew sensor (Rotation option):
The displayed information will look similar to this
-----------------------------------------------------------------------
The "ver" line indicates the software version of the rotation interface and it's creation
date.
rot is a rotation pointer and varies from 0 to ratio value minus one.
(ex. 1304 -1).
ratio is rotation sensor ratio (number of pulses for a complete rotation).
zero prox is a rotation reference point. Angle of rotation is on 'Zero prox' value
when the "proximity switch" is detecting the target.
prox detect shows "proximity switch" state. The "0" indicates that the proximity
switch is detecting a metal target set to a predetermined azimuth angle.
Detected addresses:
This page gives the sensor addresses on the CAN network detected by the i3500
system. Addresses remain in memory as long as the system is powered even if a
sensor stops communicating.

2.1.2 Error Messages and the use of the "?"

During the start up and operation processes, the i3500 system analyses all interactions
between internal peripheries (memories, controllers, extension cards, etc.) and also
external ones (physical cards linked to the Canbus network).
Telescopic cranes with derrick pressure sensors
rotation
ver: 0.11
17apr07
rot: 782
ratio: 1304
zero prox: 191
prox detect: 0
55M3500MNE rev. E
Calibration Manual i3500
10