Advertisement

Quick Links

 
 
 
 
 
 
 
 
i4500 Rated Capacity Limiter/Indicator
 
 
 
 
 
 
 
 
 
 
Copyright 2013 
(Rayco‐Wylie Systems). 
All rights reserved. 
 
Any part of this document may not be reproduced or transmitted in any form or by any means including 
photocopy  or  any  other  information  storage  and  retrieval  system  without  the  permission  from 
RaycoWylie  Systems  which  will  not  normally  be  withheld  assuming  that  the  material  is  for  internal  use 
only. 
 
 
Wylie Systems 
Drury Lane 
St. Leonards‐on‐Sea 
East Sussex 
England 
TN38 9BA 
Tel:+44 (0) 1424 421235 
Fax:+44 (0) 1424 433760 
 
Crane safety instrumentation 
 
Calibration Instructions
for
lattice boom cranes,
hoist rope load sensing
Wylie Systems 
th
1020 9
 Avenue, SW 
Suite 124 
Crane Warning Systems Atlanta
Bessemer, AL 35022 
Rayco / Wylie Sales & Service
U.S.A. 
770-888-8083 phone
Tel:+1 (205) 481‐2080 
678-261-1438 fax
Fax: +1 (205) 481‐2081 
www.craneindicators.com
http://www.raycowylie.com/
1
55M4500ECE00 REV A
 
Rayco Electronic System 
2440 Ave Dalton 
Ste‐Foy 
Québec G1P 3X1 
Canada 
Tel:+1 (418) 266‐6600 
Fax:+1 (418) 266‐6610 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i4500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RaycoWylie i4500

  • Page 1 Copyright 2013  (Rayco‐Wylie Systems).  All rights reserved.    Any part of this document may not be reproduced or transmitted in any form or by any means including  photocopy  or  any  other  information  storage  and  retrieval  system  without  the  permission  from  RaycoWylie  Systems  which  will  not  normally  be  withheld  assuming  that  the  material  is  for  internal  use  only.      Wylie Systems  Wylie Systems  Rayco Electronic System ...
  • Page 2 55M4500ECE00 REV A...
  • Page 3   All  procedures  herein  are  based  on  the  use  of  the  system  under  proper  operating  conditions, with no deviations from the original design. Alteration and/or modification  of  the  equipment  are  strictly  forbidden  without  written  approval  from  RaycoWylie  Systems.    The i4500 RaycoWylie Systems Rated Capacity Indicator (RCI) is to be regarded only as  an aid to the operator.  When the parameters are set correctly, the indicator will warn  the  crane  operator  of  an  approaching  overload  condition  that  could  cause  damage  to ...
  • Page 4 55M4500ECE00 REV A Before  operating  a  crane  equipped  with  a  RaycoWylie  system  RCI,  the  operator  must  carefully read the information in the i4500 operator manual and the crane manufacturer  operator’s  manual.  He  must  also  be  aware  of  all  the  federal,  state  and  local  safety  standard  and  regulations  applicable  to  his  job.  Correct  functioning  of  the  system ...
  • Page 5: Table Of Contents

    55M4500ECE00 REV A     TABLE OF CONTENTS    INTRODUCTION ....................6   Personnel qualification and scope of this manual .......... 6       Using this manual ....................6   CONFIGURATION ....................8     Step #1: Accessing the calibration menu ............8  ...
  • Page 6: Introduction

    55M4500ECE00 REV A 1  INTRODUCTION    This manual contains calibration information for the i4500 system. When performing  calibration of the i4500 system, always observe the safety rules and regulations  applicable in the country of operation to reduce the risk of personal injury or damage to  the equipment. Each safety instruction throughout this manual must be taken into  consideration when using the i4500 system. The information contained in this manual  will enable qualified personnel to properly operate and efficiently perform calibration.    1.1  Personnel qualification and scope of this manual     Installation of the i4500 system shall be performed by a qualified technician.  Furthermore, calibration of the i4500 system must be performed by a RaycoWylie  trained technician. The RaycoWylie technician will perform a complete and structured  verification of the whole system before beginning the system’s calibration.  Failure to calibrate the system properly can result in overloading of the crane risking  machine breakage or tipping that could result in serious injury or death. Always refer to  a RaycoWylie trained technician to calibrate your system.    1.2  Using this manual    This manual must be used in conjunction with the Instruction Manual, refer to the  instruction manual for description of the system operation, especially the section  “Operating Buttons Description”.    Screenshots used in this manual are taken from a 4.3” display and some screens may  vary on larger display versions; calibration procedures, descriptions and functions are  identical for all display versions.  All numbers shown on sample screens are examples  only and must be substituted with real information from the machine.  Navigating screens and editing data:  UP button.  Press to move up the screen when in a menu or to  increase the value of a highlighted number. DOWN button.  Press to move down the screen when in a menu or  to decrease the value of a highlighted number.  ESCAPE button.  Press to exit a menu or to escape an option ...
  • Page 7 55M4500ECE00 REV A   Additional buttons used in the calibration mode only, refer to relevant text for detailed  use: SAVE button.  Press to save all recent changes into memory. DELETE button.  Press to delete a stage of some calibrations.  CLEAR button.  Press to clear the fault log or the event log.  CHANGE SIGN button. Press to set a variable to negative or back to  positive. ...
  • Page 8: Configuration

    55M4500ECE00 REV A 2  CONFIGURATION    To ensure a successful, first calibration follow each calibration step in sequence, do not  miss out any steps unless they are marked as optional.  Many calibration screens show reminder notes or hints on the bottom line, remember  to read these for guidance.    2.1  Step #1:  Accessing the calibration menu    1‐ Press the Mode button.  2‐ Scroll to highlight “Calibration Mode” using “” or “”.  3‐ Press “” to enter this menu.  4‐ The system will request a 5 digit password. The first digit will be highlighted, use  “” or “” to select the first digit and press “” to confirm and move on to the  second digit.  Repeat this for all 5 digits, after confirming the 5  digit the system  will enter the calibration menu provided the password is correct.  If the  password is not correct the system will return to the normal working screen.  5‐ If a mistake is made while entering the password, press “” to return to the  previous digit.        Some systems are installed with dual level password access, this manual includes  information on all features accessible from the top level.  Some features will not be  available when the lower level password is entered and will not appear in the calibration  menu.  It will not normally be necessary to access these features after the initial  installation is completed.  Provided the top level password is used the calibration menu will remain accessible until  the system is powered off otherwise the password will be required every time the menu  is selected. ...
  • Page 9: Step #2: "Enable/Disable I/O" Setting

    55M4500ECE00 REV A 2.2  Step #2:  “Enable/Disable i/o” Setting     Note:  these  settings  reflect  the  configuration  of  your  system  and  will  generally  be  made during factory testing prior to delivery and should not need changing.    1‐ In the calibration menu, scroll up or down to the menu "Enable/Disable i/o".    2‐ Press “” to enter this menu.   3‐ Scroll to select the I/O option to edit.   4‐ Press “” to highlight the value to edit.  Scroll up or down to change to value  then Press “” to confirm.  5‐ Any change made must be permanently registered by pressing the “save”  button.  6‐ Press “” at any time to abandon any changes not saved or to exit the menu  when done.     As a guide, the minimum requirements for a basic system are:  Angle 1  ON  Load 1  ...
  • Page 10 55M4500ECE00 REV A             For the Generic and GPio items there are various configuration  options available once enabled, refer to the system wiring drawing    for details of which selection to set.                 ...
  • Page 11: Step #3: "Calibration Units" Setting

    55M4500ECE00 REV A   GPio HDIN’s configuration    If GPio HDIN/HDOUT is set to ON in any of the above screens then an extra menu option  will appear in the main calibration menu to configure the use of the HDIN/HDOUT  connections.    Scroll to “GPio Hdins configuration” and press “” to enter, the screen will show  options to set each GPio that has HDIN/HDOUT set to ON:    Select the pair of inputs required, press “” to highlight the option currently set, use  “” or “” to scroll through the available options and then press “save” when the  required option is displayed.  Refer to the wiring drawing supplied for the necessary  settings for your system.    Warning: these settings must match the relevant wiring drawing for proper operation  of the i4500 system.    2.3  Step #3:  “Calibration units” setting     1‐ In the calibration menu, scroll up or down to the item "Calibration units:".    2‐ Press “” to toggle between metric and imperial.    imperial:  use x1000lbs and feet.    metric:    use metric tons and metres (1 metric ton = 1000 kg).     ...
  • Page 12: Step #4: "Calibration Data" Entry

    55M4500ECE00 REV A 2.4  Step #4:  “Calibration data” Entry    Some or all of this information may be pre‐loaded prior to delivery but all entries should  be verified and edited as required before proceeding.  Length units in use will be feet or  metres depending on the setting made for ‘calibration units’ in step #3, a reminder is  shown on the bottom line of this display. Remember to save any changes made.  Please  advise Rayco Wylie of any changes required in this section.    1‐ In the calibration menu, scroll down to the item "Calibration data:".  2‐ Press “” to enter this menu.   3‐ Scroll to select the item to edit from the list below.   4‐ Press “” to highlight the value to edit.  Scroll up or down to change the value  then Press “” to confirm.  5‐ Any change made must be permanently registered by pressing the “save”  button.  6‐ Press “” at any time to abandon any changes not saved or to exit the menu  when done.      Rope limit H1:  This is the maximum tension that the cable is rated for per fall or part  of line (rope SWL) for the main rope.   Rope limit H2:  This is the maximum tension that the cable is rated for per fall or part  of line (rope SWL) for the auxiliary rope.   Rope limit H3:  This is the maximum tension that the cable is rated for per fall or part  of line (rope SWL) for the first whip rope.   Rope limit H4:  This is the maximum tension that the cable is rated for per fall or part  of line (rope SWL) for the second whip rope.  ...
  • Page 13 55M4500ECE00 REV A  Alarm 1:  Is the %SWL approach limit.  If the %SWL is greater than Alarm 1, an  intermittent audible alarm will be activated and the yellow display LED will blink.  The  external yellow lamp output will be ON.  Note: %SWL = (Load / Capacity) x 100.   Alarm 2:  Is the %SWL overload limit. If the %SWL is greater than Alarm 2, a  continuous audible alarm will be activated and the red display LED will be ON. The  external red lamp and audible alarm output will be ON.    Alarm 3:  Is the %SWL motion cut limit. If the %SWL is greater than Alarm 3, a  continuous audible alarm will be activated and the red display LED will be ON.  The  external red lamp and audible alarm output will be ON.  The motion cut output will  be in the stop condition (cut active).    Outside duty radius:  This variable represents a transition distance between the  maximum radius rating and zero capacity, the SWL will decay evenly from the last  point on the chart to zero over the distance set by this variable and applies to all  charts.  Note: This option is valid only if the chart interpolation (in the system options menu)  is set to "ON".    Outside duty angle:  This variable works in the same way as ‘outside duty radius’ but  is used for charts where the SWL is determined by boom angle and not radius.   Outside duty length:  This variable represents an upper tolerance on the automatic  selection of the relevant load capacity chart for the actual boom length.   Number of hoists: Set to the number of hoists (winches, or hooks) fitted to the crane,  1  for  main  hoist  only  or  2  for  main  and  auxiliary  hoists  etc.    up  to  4  hoists  are  available. ...
  • Page 14: Step #5: "Dimensions" Data Entry

    55M4500ECE00 REV A 2.5  Step #5:  “Dimensions” Data entry     This menu contains crane dimensions that are necessary for the calculation of the load  radius and height of the boom tip.    Some or all of this information may be pre‐loaded prior to delivery but all dimensions  should be verified and edited as required before proceeding.  Units in use will be feet or  metres depending on the setting made for ‘calibration units’ in step #3, a reminder is  shown on the bottom line of this display.  To enter a negative value, enter the number  and press “+/‐“ to change the sign.  Press “+/‐“ again to toggle back to a positive value.  Remember to save any changes made.  Please advise Rayco Wylie of any changes  required in this section.  Dimensions relating to boom tip attachments and the boom lengths are stored in the  chart file and are not editable in this menu, *see note 1   SCF (slew offset) – horizontal distance between the boom foot pin and the centerline  of rotation of the machine.  If the boom foot pin is behind the centerline of rotation  then the distance is negative, otherwise it is positive.   CH1 (height rubber)  vertical distance between the boom foot pin and the ground  –  when on tires or crawlers.   CH2 (height outrigger)  vertical distance between the boom pivot pin and the  –  ground when on outriggers.  For crawler based machines set to the same value as  CH1.  *Note 1:  The chart file that contains all the relevant load charts and duty information  for the machine also contains dimensions for the boom lengths and all the boom top  attachments (fly jibs etc.).  In some cases some of this data may not have been  available during the system configuration at the factory.  In these cases it will be  necessary to obtain the information by surveying the hardware on site, the attending  Rayco Wylie technician will be equipped to update the load chart file with this data.   In the event of a Rayco Wylie technician not attending please refer to the sketches  below and contact Rayco Wylie Systems technical service and provide them with the  missing dimensions.  The load chart file will be updated with the verified information ...
  • Page 15 55M4500ECE00 REV A Note sign convention: All dimensions shown positive, if the boom foot pin is behind the centreline of rotation then SCF will be negative.
  • Page 16: Step #6: "Block Capacities And Block Weights" Setting

    55M4500ECE00 REV A     2.6  Step #6:  “block capacities and block weights” setting    This menu contains the capacities and weights of all the available hooks for the crane,  the hook(s) in use must be entered here for subsequent selection in the configuration  setting of the system.  The capacity of each hook will be used by the i4500 system to  determine whether the current SWL for the configuration and position of the machine is  limited by the load curve, the parts of line or the hook capacity.  After selecting “block capacities and block weights” from the main calibration menu the  screen will show:  Set the capacity and weight of each hook block in turn using the calibration units set  earlier (noted at the bottom of this screen).  Remember to press “save” once all the  data is entered.  Numbers shown are for illustration purposes only and must be set to  show real data from the machine. ...
  • Page 17: Step #7: "System Options" Setting

    55M4500ECE00 REV A 2.7  Step #7:  “system options” setting    The system options menu allows various features to be turned on and off and may vary  depending on the version of software installed in the i4500 system.  These settings will  normally be pre‐set before delivery and will not require changing.  Navigate through the calibration menu using “” or “” to highlight “system options”  and press “” to enter.      Chart interpolation.  Determines whether or not the i4500 system interpolates the  crane capacity charts with respect to radius/angle or whether it steps from one capacity  to the next. If chart interpolation is ON, the system will display a smooth transition  between rated points. If it is OFF, then once the radius/angle exceeds a listed value on  the chart the capacity will drop to the next rated capacity, this is known as a stepped  chart. Refer to the crane manufacturer’s load chart to determine if the charts should be  interpolated or stepped.  Datalogger.  Allows the datalogger, if fitted, to be switched ON or OFF.  Crane ID. This is only used if a datalogger is installed and is a unique identifier for the  crane.  It is used in conjunction with the Rayco Wylie data logger software for PC to  manage ‘whole life’ data for the machine and acts as an identifier for files once  downloaded and removed from the machine.  Password protection. This is only used if a datalogger is installed and, when set to ON,  will set the system to ask for a pass code number to be entered each time the system is  switched on.  See also “user id” settings (page 31).  “Limit saved” message. Optional feature, if enabled then setting this to ON will display  a message on start up indicating a limit is saved if a limit has previously been set.  Limit access with HDIN. When set to ON, Limits menu is accessed via an external input  rather than the normal menu button.  Refer to the wiring diagram for details if relevant.  External setup button. Optional feature, if enabled then setting this to ON will allow  the setup bypass feature to be available via an external digital input. ...
  • Page 18: Step #8: "Bridging/Bypass Output

    55M4500ECE00 REV A Return time from limits. Not enabled unless the range limiting feature is fitted.  This  value represents the time allowed between setting a range limit and the limit becoming  active to allow the machine to be moved back into the permitted working zone.   2.8  Step #8:  “bridging/bypass output”    This item is an option depending on the version of the software installed.  When  available it allows the parameters to be set for the PWM output used to reduce the  machine speed during bridging or bypass functions.    2.9    Step #9:  “picture”    This setting allows the graphic of the crane shown in the normal working window to be  set to a version that looks similar to the machine to which the system is fitted.  It can be  set to any of the available choices at any time without changing the performance of the  system.     ...
  • Page 19: Calibration

    55M4500ECE00 REV A 3  CALIBRATION    3.1  Step #10:  “Zero sensor/Side of boom angle” angle sensor calibration     Address selection dip switch:  Every angle sensor installed has its own dedicated address.  These switches are factory  set prior to dispatch and will not normally require changing.  Please refer to the wiring  diagram to see the address dip switch setting for each angle sensor interface.      Angle Sensor Side of Boom:  1) Use “” or “” to choose “select sensors” and press “”.    2) Use “” or “” to choose the relevant angle sensor and press the “”.    3) Use “” or “” to choose “span sensor or side of boom angle” and press “”.   ...
  • Page 20 55M4500ECE00 REV A 4) Press “” to highlight the value to edit and use “” or “” to edit the location  of the angle sensor, press the “” to confirm and then “” to exit.    Note, “right” indicates right hand side of boom (or inside left hand side facing right)  when viewed from the operator’s cab.    Zero angle calibration:     Ensure the correct side of boom setting has been made before setting the zero datum, if  the side of boom setting is changed then the zero setting must be repeated.     1) Use “” or “” to choose “Zero sensor” and press “”.    2) Boom down to zero degrees (main boom horizontal) using a precision angle  measure to accurately establish the true angle of the base boom section.  The  angle is displayed in degrees and the sensor value is in bits.  This value must be  above 100 bits.  If smaller, turn the sensor to increase the value.  3) Press “” to edit the angle value using “” or “”.  4) Press “” again to confirm the zero.  5) Press “” to return to the main calibration menu.  The boom angle need not be zero but it’s true value must be accurately known and  entered as described.  Note that the angle sensor(s) do not require a span calibration.  Repeat step #10 for each angle sensor in turn.       ...
  • Page 21: Step #11: "Zero Load/Span Load" Sensor Calibration

    55M4500ECE00 REV A 3.2  Step #11:  “Zero load/Span load” sensor calibration    When calibrating load sensors, always slowly hoist and stop the test loads smoothly in  order to eliminate errors in the load reading due to frictional effects.  The frictional  effect on dynamometer (line rider) systems will cause the displayed load to decrease  when lowering the load and to increase when hoisting the load.  On dead‐end load cell  systems this effect is reversed.  These friction effects can be minimised by ensuring  boom head sheaves and hook block are in good condition and properly maintained  before proceeding.  Warning:  The system does not store the ZERO LOAD into permanent memory until the  SPAN LOAD calibration has been completed.  If a ZERO LOAD calibration is done, then a  SPAN LOAD calibration must also be done.  Load sensor calibration must be done with two, accurately known test loads, a small  load and a large load.  The large calibration load should provide between 50‐90% line  pull on the hoist line while using as many parts of line as is feasible.  If a large enough  load cannot be found, the crane can be reeved to fewer parts to increase the line pull  for a given calibration load.  The smaller load should be approximately 5‐10% of the  larger load and in many cases the block weight alone may be sufficient.  The calculated   test loads should normally include the weight of the hook block and any slings, shackles  etc. that are used.  Select the load sensor to be calibrated  1) Use “” or “” to choose “Select load sensor” and press “”.    2) Use “” or “” to select the relevant load sensor and press “”. ...
  • Page 22 55M4500ECE00 REV A   3) Use “” or “” to select the parts of line currently rigged on the hook to be  calibrated and press “” to confirm the selection and return to the main  calibration menu.    Zero load calibration:  1) Use “” or “” to choose “Zero load” and press “”.    To zero the load sensor, position the boom at a safe radius for the large test load but  attach and slowly lift the small test load until it is just clear of the ground.  The reading on the Sensor value is in bits and the maximum scale value is 4095. For the  zero setting the display should read between 175 and 300 bits. The units for calibration  are shown at the bottom of the screen.   2) Press “” to edit the zero value.  3) Edit the zero value to read the value of the suspended test load, then press “”  to confirm the value.  Note the indicated value will return to it’s earlier state  temporarily, the new zero value will be stored after the next step.  4) Press “” to return to the main calibration menu.       ...
  • Page 23 55M4500ECE00 REV A Span load calibration:    1) Use “” to choose “Span load” and press “”.      To span the load sensor, position the boom at the same safe radius for the large test  load as above and slowly lift the large test load until it is just clear of the ground.  As above, the reading on the bottom line represents the current bits value of the sensor,  for the span setting the reading should not be greater than the values shown in the  following table depending on the size of the calibration load but should be as close to  these figures as possible.  Note, values for test loads greater than 90%SWL are shown  for reference only and should not be used for calibration purposes.  Test load  50%  60%  70%  80%  90%  100%  120%  Max Bits value  1765  2100  2430  2765  3100  3430  4095    If the reading is unacceptable then adjust the gain setting jumpers in the transducer  interface unit to achieve the closest possible setting, refer to the label inside the  interface unit for guidance.  The standard gain setting number is 325, other options are  219, 253, 413, 579 and 630; a higher gain setting will result in a larger span setting  value.    Warning:  If the gain value is changed then redo the zero load calibration before  continuing with the span load calibration.  2) Press “” to edit the span load value.    3) Edit the span value to read the value of the suspended load, then press “” to ...
  • Page 24: Step #12: "Loaded Boom Deflection

    55M4500ECE00 REV A 3.3  Step #12:  “Loaded boom deflection”    This procedure is optional depending on the accuracy of the radius indication, it is used  to add an allowance into the calculation of the hook radius to compensate for main  boom and/or chassis deflection due to a suspended load.  A separate calibration is  available for each and every boom length.  This procedure should only be used with machine configurations on outriggers or on  crawlers.    A known test weight is required to carry out this calibration, the weight should be  between 50% and 90% of the SWL for the configuration being calibrated and should be  based on the SWL with the boom at approximately 60° boom angle.  The calculated test  load should normally include the weight of the hook block and any slings, shackles etc.  that are used.  Ensure the current duty selection matches the actual crane configuration to be  calibrated.    1) Use “” or “” to highlight “Loaded boom deflection”  and press “” to enter.    The display will show the current boom angle followed by a target boom angle for  calibration, normally 60°.    Adjust the boom angle to the target angle, when the boom is at the correct angle for  calibration, the display will change to show ok.    2) Press “”, the display will change to show:   ...
  • Page 25: Step #13: "Friction Compensation

    55M4500ECE00 REV A Carefully lift the test load until it is just clear of the ground.  Accurately measure the  actual radius of the suspended load from the centre line of slew of the machine.  3) Use “” or “” to adjust the Corr.: x.xx value until the displayed radius equals  the measured radius, note that the indicated radius can only be increased, not  decreased.  Press “” to accept the change, the system will confirm the  calibration is saved.  4) Press “” to return to the main calibration menu.    Carefully set the test load on the ground.    3.4    Step #13:  “Friction compensation”  This feature is optional and only available if additional sensors have been fitted to sense  rope direction.  If no sensors are fitted then all values in this step must be set to 0.00  (default value).  The feature allows for the effect of friction in multi part reeving systems to be calibrated  to give a more consistent load reading on the display irrespective of direction of hoisting  of the load.    Friction compensation should only be done once the load calibration and deflection  calibrations have been completed.  Two friction compensation value sets are available,  one for the main hoist and one for the aux hoist.  Friction compensation is not available  for other hoists.  Calibration is achieved using the large load as described in step #11 and is done in three  stages:  Stage 1 – record the load indication errors  The basic calibration performed in step #11 is done with the load static after hoisting  and the rope system friction characteristics for this condition are incorporated  automatically.  Three other friction characteristics can be set as required, they are:  dynamic hoisting, dynamic lowering, and static after lowering.  Slowly hoist the test load and note the displayed value of load while the load is in  motion, repeat the test several times until an acceptable average figure is established.   Record this average reading.  Repeat this test while slowly lowering the test load and  record the average reading established for lowering.  Repeat the test again and, this  time, record the average reading of the load display when the load remains suspended  but static after lowering.  Stage 2 – calculate the compensation factors ...
  • Page 26 55M4500ECE00 REV A Worked example:  Test load (including hook block and slings etc.) = 40te  Parts of line = 8  Average load reading when hoisting = 42.0 te  Average load reading when lowering = 37.0 te  Average load reading when static after lowering = 39.0te  Hoisting factor (%)   =   (40.0 – 42.0) x 100    =   ‐0.63%  40.0 x 8  Lowering factor (%)   =   (40.0 – 37.0) x 100    =   +0.94%  40.0 x 8  Lower static factor (%)   =   (40.0 – 39.0) x 100    =   +0.31%  40.0 x 8  note negative value for dynamic hoisting.  Stage 3 – enter the compensation factors into the calibration    1) Use “” or “” to highlight “friction compensation” and press “” to enter.  2) Use “” or “” to highlight the required hoist and press “” to select and move  to the next screen:    3)  the value for editing, 0.00 indicates that no friction compensation is applied.  Change the values to those calculated above and press “” to confirm.  4) Press “save” to record the changes.  5) Press “”  to exit the calibration mode and retest the performance to establish  the effect, return to the friction calibration and modify if required. ...
  • Page 27: Step #14: "Transfer" Calibration Backup

    55M4500ECE00 REV A 3.5    Step #14:  “Transfer” Calibration backup  A copy of the calibration file can be made at any time after completing a calibration step  and should be made once the final calibration is completed.  Note a USB memory stick  must be connected to connector ‘B’ of the i4500 display unit using a Deutsch to USB  converter lead (RaycoWylie part no. 33V0414) before proceeding.     1) Use “” or “” to highlight “transfer” and press “” to enter.      2) Select “transfer from system to USB (backup)” ” and press “”      3) Select “calibration ‐> USB stick” ” and press “”, a copy of the calibration  information will be created in a file called “cranename_000000.cal” located in  the root folder of the USB memory stick.  If a file of this name already exists ie a  previous backup has been made then the new file will become  “cranename_000000‐1.cal” etc.  The final completed calibration file should be renamed:  “cranename_serialnumber_date_tech.cal”  where serialnumber is the serial number of  the i4500 system, the date is the date the calibration file is completed/downloaded and  tech is the initials of the calibrating technician.  A copy of this file should be sent to Rayco Wylie for archive purposes.     ...
  • Page 28: Transfer" Restoring Calibration And Load Chart Files

    55M4500ECE00 REV A 3.6    “Transfer” restoring calibration and load chart files  Warning:  This procedure will overwrite the existing data in the i4500 system and the  existing data will be lost.  It is advisable to archive copies of the existing data using the  procedure in step #14 as a precaution before continuing.  If in doubt consult Rayco  Wylie.  A copy of the calibration and/or load chart files can be restored to the i4500 system at  any time.  Note a USB memory stick must be connected to connector ‘B’ of the i4500  display unit using a Deutsch to USB converter lead (RaycoWylie part no. 33V0414)  before proceeding.  Ensure the file required to be restored is saved in the root folder of  the USB stick.  Navigate through the calibration menu using “” or “” to highlight “transfer” and  press “” to enter.      Select “transfer from USB to system” ” and press “”    To restore a load chart file select “usb stick ‐> Load chart” ” and press “” or to restore  a calibration file select “usb stick ‐> Calibration” ” and press “”,    ...
  • Page 29: Memory

    55M4500ECE00 REV A A list of files will be displayed, either “xxxx.cf” or “xxxx.cal” depending on the choice  above.  Note that only files located in the root folder of the USB stick will be displayed.   Select the relevant file from the list displayed and press “”, the selected file will be  copied to the i4500 system and will replace any existing data.  Once done, it is advisable to reboot the system (power off and on again) and reselect a  valid configuration, do not accept the existing default duty presented on start up.    3.7    “Memory”    Warning:  Initialising memory A will delete all the information stored in the calibration  memory, be sure you have made a backup copy of the calibration file before using this  option – if in doubt, don’t!    initialize memories A and C  Select this option to re‐initialize the system memory, a warning screen will be displayed  to ask for confirmation, if confirmed all calibration data will be deleted.  initialize memory C  Select this option to re‐initialize the memory for the current configuration, only data  related to the current operator settings will be deleted ie duty number, parts of line  settings etc.  Reset the duty configuration immediately after initializing memory C.   ...
  • Page 30: Options

    55M4500ECE00 REV A 4  OPTIONS    4.1  “Limits setting” parameters    This menu contains the approach warning gaps for all the limits that can be set by the  operator in normal mode.  Note: if range limiting is fitted then this menu is not available  and the limit parameters should be set using the rotation data menu below (p31).  After selecting “limits setting” from the main calibration menu the screen will show:  Set the approach gap for each limit in turn, angle approach gaps are in degrees, radius  and height gaps are set using the calibration units.  Remember to press “save” once all  the data is entered.  4.2  “special calibration”  This section will contain calibration settings for special features if enabled and will be  described in a separate addendum to this manual. 4.3  “Users ID” Setting user pass codes for the data logger  This feature is only used if the data logger feature is fitted to the system and password  protection is set to ON.  It is a list of password numbers used to log into the i4500 on  startup and can be used in conjunction with the Rayco Wylie data logger software for PC  to record individual user data for each working session of the machine.  Where this  feature is not used the default login number is “99999”.  Navigate through the calibration menu using “” or “” to highlight “users id” and  press “” to enter.   ...
  • Page 31: Rotation Data

    55M4500ECE00 REV A Scroll down to the first “0” entry and press “” to highlight the value for editing, (0  indicates an unset value and is not a valid login number) change the 5 digit number to  the required code and press “save” to accept the change, press “” to return to the  main calibration menu.  There are 100 different code numbers available to set including  the default value.  To delete a number, change it to “00000” which is not a valid id number.    Note: It is recommended that the default value of “99999” is retained and new entries  made from position 2 onward but if the default value is changed remember to safely  record the new value.  The i4500 system must have a valid number entered before it will  go to the normal working screen if password protection is set to ON.    4.4  “rotation data”  This feature is only available if the range limiting feature is fitted to the system or a  sensor is used to monitor the slew position of the crane for duty selection.  Navigate through the calibration menu using “” or “” to highlight “rotation data”  and press “” to enter.      Rotation direction:  set to CW (clockwise) or CCW (counter‐clockwise) as required to  ensure that the slew angle reading increases when the machine is slewed to the right as  viewed from the operators’ position.  Approach zone height:  this value represents the approach warning gap for the height  limit in the units set for calibration.  Approach zone wall:  this value represents the approach warning gap for the slew limit  in degrees.  Approach zone radius:  this value represents the approach warning gap for the radius  limit in the units set for calibration.     ...
  • Page 32 55M4500ECE00 REV A Absolute zero:  This is used to set the zero datum point when an absolute encoder or  single turn, twin wiper potentiometer is fitted as the slew sensor.  To set the zero  datum:  Rotate the machine to the zero datum point, normally centred over the front of the  machine, and press “” to set the slew angle reading to zero and permanently store  this point.  If the encoder is a multi‐turn type then set the ratio first before setting this zero point  (see below).  Encoder type:  This will be factory set and should not be changed.  It represents the type  and manufacturer of the encoder that is fitted.  Ratio:  This value will only be available if a multi‐turn encoder is specified above and  represents the number of turns that the encoder rotates for a single 360° rotation of the  crane.  To set this ratio:  1) Position the crane at an identifiable slew position and check that it will be safe to  rotate the machine for a full circle.  2) Select “ratio” and press  “”.  When ready to start the recording process press  “” again and rotate the machine 360° and return to the exact start point.  3) When satisfied that the machine is exactly one turn from the start, press “” to  confirm the position and press “save” to store it to memory.  4) Press “” to return to the main calibration menu.   ...
  • Page 33: Automatic Logs

    55M4500ECE00 REV A 5  AUTOMATIC LOGS  5.1  “Fault log”  The fault log screen is a diagnostic tool used to record intermittent errors detected in  various parts of the system.  The numbers on the right hand side of this screen  represent a count of the number of individual faults detected for each component and  can be useful in tracing system faults.  Navigate through the calibration menu using “” or “” to highlight “fault log” and  press “” to enter.    Note the fault status, press “” to return to the main calibration menu or press “XX” to  reset all the counters to zero.  5.2  “Event recorder”  The event recorder provides a summary of lifts performed in each 10% band of SWL, it  also provides a count of ATB and bypass activations.  Note:  the event recorder does not  replace the data logger feature as no date and times are recorded, the counters can be  reset at any time and event data is not downloadable for external analysis.  Navigate through the calibration menu using “” or “” to highlight “event recorder”  and press “” to enter.    Note the event status, these sample screens show 2 lifts performed between 50 and  60% SWL and also 2 ATB alarms recorded.  Press “” to return to the main calibration  menu or press “XX” to reset all the counters to zero. ...

Table of Contents