Step 3:
Afterwards, the I-7590 utility shows all settings stored in the I-7590 if it had
been configured before, or shows "User Defined" if there is no configuration. If
users want to clear the setting before, click the "Clr" button behind the item to
clear the corresponding configuration. If users want to configure a new Baud rate
and data format, select an empty item, key in the Baud rate and data format, and
click the "Set" button to finish the configuration.
The I-7590 supports Data Bit: 5, 6, 7, 8.
Parity: n, e, o, 1, 0.
Stop Bit: 1, 2.
Note: Some Baud rate can't been exactly calculated as the same with the
users' configuration. The utility would choose a closest Baud rate
instead (the tolerance is depend on the value of the Baud rate, and
would not exceed 3%). For example, if the 115200 bps is
configured, the 115089 bps will be used.