Dimplex RKHA Series Manual page 2

Under cabinet heater
Hide thumbs Also See for RKHA Series:

Advertisement

2. Cut 22 ⅜ in (568 mm) x 3 ⅝ in (92 mm) opening (Figure
2). Keep clearance area free of obstructions.
3. Bring in service cable to left or rear of 10 in (254 mm)
minimum area as shown in Fig. 2.
4. Remove heater cover and appropriate knockout. Attach
service cable to unit with approved connector and connect
the appropriate power wires in outlet box. To change
wattage or voltage connections, see Figure 5.
5. Replace cover, slide unit into opening, and secure each
side (Figure 1).
! NOTE: Make sure unit is installed right side up. Refer
to "TOP" label.
Soffit or Stair Riser Installation
1. Cut opening as for heater installation (22 ⅜ in
(568 mm) x 3 ⅝ in (92 mm)). Allow ¾ in (19 mm) clearance
below cabinet doors. Add supports for unit (Figure 3).
2. Proceed as for heater installation. After securing unit in
opening, install combination of frame and grille if desired
(Figure 1).
Operation
WARNING: This heater must be properly installed before it
is used.
1. Prior to powering on the unit, remove all construction dirt
(plaster, sawdust, etc.) from interior and exterior of heater.
2. If the unit is installed using the field-installed built-in
thermostat (CKHATD23), adjust the thermostat with pliers.
This unit can also be controlled from a line voltage single
pole or double pole wall thermostat.
Dimplex Under Cabinet heaters are designed and tested
for safe and trouble-free operation and are protected
against overheating by a built-in thermal cutout. Free airflow
throughout the heater is extremely important for the most
efficient operation of the heater. Restricted airflow may cause
the thermal overload protector to cycle the heater "ON and
OFF". A cycling heater will not supply sufficient heat to the
room.
Avoid direct contact of paper, fabric, or furniture with heater.
2
FIGURE 1
Heater Cover
Top Label
Junction Box Cover
Screw 'C'
Screw 'A'
FIGURE 2
10" MIN.
10" MIN.
Service
SERVICE
CABLE
Cable
22"
22"
KNOCKOUTS
Knockouts
FIGURE 3
CEILING
GRILLE
HEATER
CABINET
DOOR
FIGURE 4
CABINET
DOOR
HEATER
GRILLE
FLOOR
Heater
Element
Screw'B'
Grille
Optional Grille Frame
22 3/8"
22-3/8"
3 5/8"
3-5/8"
3-1/2"
3 1/2"
9-1/2"
9 1/2"
CLEARANCE 5" MIN.
3/4"
MIN.
PARTITION
OR ADDED
SUPPORT
PARTITION
OR ADDED
3/4
SUPPORT
MIN.
www.dimplex.com