Download Print this page
Dimplex RKHA Series Manual

Dimplex RKHA Series Manual

Under cabinet heater
Hide thumbs Also See for RKHA Series:

Advertisement

Quick Links

IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the heater.
2. The heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater
outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding,
papers, clothes, and curtains at least 3 ft (0.9 m) from the front of the unit and keep them away from the sides
and rear.
3. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is
left operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect power at the service panel and have the heater
inspected by a reputable electrician before reusing.
5. Do not use outdoors.
6. To disconnect the unit, turn the controls off, and then switch off at main power supply panel.
7. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric
shock or fire, or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust in any manner.
9. All electrical heaters have hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or
flammable liquids are used or stored.
10. Do not modify this heater. Use it only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons.
Installation Instructions
WARNING: To reduce the risk of fire, do not store or use
gasoline or other flammable vapors or liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of fire, keep electrical
cords, drapery, furnishings, and other combustibles at least
3 feet (0.9 m) from the front of the heater.
! NOTE: It is extremely important to read all information
labels. Care must be taken to ensure that the heater
is rated the same voltage as the electrical supply wires.
Failure to do so could result in unsafe heater operation as
well as damage to the unit. If replacing an existing heater,
check the labels of the old heater to ensure the voltage of
the new heater is compatible.
! NOTE: Care must be taken to prevent undue strain on all
wiring or heating element assembly, when removing and
re-assembling heating element assembly.
CAUTION: For field rewiring to 120V all leads must be
secured under wire clamps.
SAVE THESE INSTRUCTIONS
Under Cabinet Heater
RKHA Series
! NOTE: Air and grille temperatures conform to CSA & UL
regulations but may discolour certain materials, particularly
those materials incorporating clear vinyl. Materials should
be checked prior to installation to determine if discolouration
or distortion would occur in the vicinity of 60° C (140° F)
! NOTE: This heater needs to be installed with a line voltage-
thermostat or the optional built-in thermostat (CKHATD23)
Under Cabinet Heater Installation
! NOTE: Unit should be installed so that it is not directly under
sink or other frequently used work area as air temperature
may be uncomfortably warm. Also, if carpeting is on floor,
mount unit so bottom of grille is level or above the top of the
carpet pile.
1. Measure area of intended use. The optional grille trim may
be used if required. Otherwise the frame may be removed
by removing grille frame from heater (screw "A"), remove
frame and re-insert grille.
7200960100R013

Advertisement

loading

Summary of Contents for Dimplex RKHA Series

  • Page 1 Under Cabinet Heater RKHA Series IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the heater.
  • Page 2 This unit can also be controlled from a line voltage single GRILLE PARTITION HEATER pole or double pole wall thermostat. OR ADDED Dimplex Under Cabinet heaters are designed and tested SUPPORT for safe and trouble-free operation and are protected CABINET against overheating by a built-in thermal cutout. Free airflow DOOR throughout the heater is extremely important for the most efficient operation of the heater.
  • Page 3 IMPORTANT: Terminate unused leads with wire nuts and 900W / 7.5A 7-8, 1-2 1350W / 11.2A 7-8, 1-2, 3-4 retighten all leads with cable clamp 1800W / 15A 7-8, 1-2, 3-4, 5-6 FIGURE 5a THERMOSTAT NOTE: See supplemental wiring diagram for thermostat wiring, Figure 5a. www.dimplex.com...
  • Page 4 Cutout (Automatic) 211A619RP Grille Kit (Black) CKHABG Grille Kit (White) CKHAWG Grille Kit (Silver) CKHASG 1-888-346-7539 | www.dimplex.com In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice. © 2019 Glen Dimplex Americas...