Nokia Customer Care
Flash Programming Error Codes
The following characteristics apply to the information in Table 4.
• Error codes can be seen from the test results or from Phoenix's flash-tool.
• Underlined information means that the connection under consideration is being
used for the first time.
Error
Description
C101
"The Phone does not set FbusTx line high after
the startup."
C102
"The Phone does not set FbusTx line low after
the line has been high. The Prommer generates
this error also when the Phone is not con-
nected to the Prommer."
Issue 2 05/2005
Figure 12: Flashing, continued 2
Table 4: Flash Programming Error Codes
©2005 Nokia Corporation
6255/6255i6256/6256i (RM-19)
Baseband Description and Troubleshooting
Not Working Properly
Vflash1
VBatt
BSI and FbusRX from prommer to UEME.
FbusTx from UPP->UEME->Prommer(SA0)
PURX(also to Safari)
VR3
Rfclock(VCTCXO->Safari->UPP)
Mbus from Prommer->UEME-
>UPP(MbusRx)(SA0)
FbusTx from UPP->UEME->Prommer(SA1)
BSI and FbusRX from prommer to UEME.
Company Confidential
FLASH_3
CH1 = PURX
CH2 = MBUS
CH3 = FBUSTX
CH4 = FBUSRX
M easure points
Production test pattern
(J396)
Data transfer has
started (Fbus_Rx)
Page 23