Flash Programming Error Codes - Nokia RH-66 Troubleshooting Manual

Baseband description and troubleshooting
Hide thumbs Also See for RH-66:
Table of Contents

Advertisement

Nokia Customer Care

Flash Programming Error Codes

The following characteristics apply to the information in
• Error codes can be seen from the test results or from Phoenix's flash-tool.
• Underlined information means that the connection under consideration is being
used for the first time.
Error
Description
C101
"The Phone does not set FbusTx line high after
the startup."
C102
"The Phone does not set FbusTx line low after
the line has been high. The Prommer generates
this error also when the Phone is not con-
nected to the Prommer."
C103
" Boot serial line fail."
C104
"MCU ID message sending failed in the Phone."
C105
"The Phone has not received Secondary boot
codes length bytes correctly."
C106
"The Phone has not received Secondary code
bytes correctly."
C107
"The Phone MCU can not start Secondary code
correctly."
C586
"The erasing status response from the Phone
informs about fail."
C686
"The programming status response from the
Phone informs about fail."
Cx81
"The Prommer has detected a checksum error
in the message, which it has received from the
Phone."
Cx82
"The Prommer has detected a wrong ID byte in
the message, which it has received from the
Phone."
Issue 1 03/2005
Table 3: Flash Programming Error Codes
©2005 Nokia Corporation
2115i/2116/2116i (RH-66)
Baseband Description and Troubleshooting
Table
Not Working Properly
Vflash1
VBatt
BSI and FbusRX from prommer to UEMC.
FbusTx from UPP->UEMC->Prommer(SA0)
PURX(also to Safari)
VR3
Rfclock(VCTCXO->Safari->UPP)
Mbus from Prommer->UEMC-
>UPP(MbusRx)(SA0)
FbusTx from UPP->UEMC->Prommer(SA1)
BSI and FbusRX from prommer to UEMC.
Mbus from Prommer->UEMC-
>UPP(MbusRx)(SA1)
FbusRx from Prommer->UEMC->UPP
FbusTx from UPP->UEMC->Prommer
FbusTx from UPP->UEMC->Prommer
Mbus from Prommer->UEMC->UPP(MbusRx)
FbusRx from Prommer->UEMC->UPP
FbusTx from UPP->UEMC->Prommer
Mbus from Prommer->UEMC->UPP(MbusRx)
FbusRx from Prommer->UEMC->UPP
FbusTx from UPP->UEMC->Prommer
UPP
Flash
Flash
FbusTx from UPP->UEMC->Prommer
FbusTx from UPP->UEMC->Prommer
Company Confidential
3.
Page 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

2115i21162116i

Table of Contents