Battery Charging; Figure 9: Battery Charging - Nokia NSB-5 Series Technical Documentation Manual

System module
Hide thumbs Also See for NSB-5 Series:
Table of Contents

Advertisement

NSB-5
System Module
and the VCXO power control, VCXOPwr is set low. In this state only the 32 kHz sleep
clock oscillator in CCONT is running. The flash memory power down input is connected to
the VCXO power control, so that the flash is deep powered down during sleep mode. Dur-
ing sleep mode, the phone wakes up periodically to page the base station for incoming
calls, location update, etc. The paging rate is a parameter set by the BS.
The sleep mode is exited either by the expiration of a sleep clock counter in the
MAD2WD1 or by some external interrupt, generated by a charger connection, key press,
headset connection, etc. The MAD2WD1 starts the wake up sequence and sets the VCX-
OPwr control high. After VCXO settling time other regulators and clocks are enabled for
active mode.
If the battery pack is disconnect during the sleep mode, the CCONT shall power down the
SIM in the sleep mode as there is no time to wake up the MCU.

Battery charging

The electrical specifications give the idle voltages produced by the acceptable chargers
at the DC connector input. The absolute maximum input voltage is 30V due to the tran-
sient suppressor that is protecting the charger input. At phone end there is no difference
between a plug–in charger or a desktop charger. The DC–jack pins and bottom connector
charging pads are connected together inside the phone.
MAD
0R22
VBAT
ICHAR
PWM_OUT
MAD
CCONTINT
VCHAR
CCONT
GND
Page 24
LIM
TRANSCEIVER
VOUT
CHAPS
33R/100MHz
27pf
RSENSE
VCH
1u
GND
PWM
47k
22k
1n
47k

Figure 9: Battery Charging

Nokia Mobile Phones Ltd.
PAMS Technical Documentation
CHARGER
1.5A
VIN
30V
EMI
CHRG_CTRL
NOT IN
ACP–7/8
L_GND
Issue 1 03/01