JDS Uniphase SCG Series User Manual page 31

Fiberoptic switch
Table of Contents

Advertisement

CONFIG?
Query Switch Configuration
Returns a data stream containing a number of packets equal to the number of switches within
the unit, with each packet separated by a semicolon (;) delimiter. Each data packet contains:
One integer representation of the switch number
Two characters representing the switch designation
One integer describing the output channel currently connected to input channel one
One integer defining the board or motor address of the switch
Two integers defining the numbers of the first and last relay lines used by this switch (if
motor, these are 0)
One integer defining the number of input channels
One integer defining the number of output channels
LRN?
Learn
Returns a string containing the commands that, if sent, reset the currently selected switch to its
current state, for example, SWITCH I J K;SRE L, where I represents the switch number, J
represents the input channel number, K represents the output channel number, and L
represents the value of the service request enable register.
STB?
Status Register
Returns a three-digit integer and automatically clears the status register if the SRQ bit is set.
SRE?
SRQ Mask
Returns the contents of the SRQ mask register.
CNB?
Condition Register
Returns the contents of the condition register.
TST?
Self-test
Executes a verification operation on all installed stepper motor type switches. An error code that
can be queried with ERR? or LERR? is placed in an error queue. The query TST? also sets bit
7 in the status register.
0 = self-test passed
1 = self-test failed
Programming Guide – 28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scg-dScg-eScg-f

Table of Contents