Example of wiring connection to Card Key Unit will be as below (reference only)
CARD KEY UNIT (Prepared by INSTALLER)
Card sensor
indicator
AC
POWER
SUPPLY
•
CONNECTION EXAMPLE
i. Pin No. 3 of DIP SWITCH is set to OFF position (HI Input Active) for Dry Contact Type a
Connecting cord to PCB
Accessory# SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
Indoor unit
SERIAL CONNECTION
All SW ON → OPERATION
ii. Pin No. 3 of DIP SWITCH is set to ON position (LO Input Active) for Dry Contact Type b
Indoor unit
PARALLEL CONNECTION
All SW OFF → OPERATION
Please refer to the actual manual supplied with the optional connecting cords SPX-WDC2/WDC3 for more details.
Dry contact
Connection
PWB
Connection
Connecting cord to PCB
Accessory# SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
PWB
Connection
② Contact with sleeve
① Connecting Cord to PCB:
SPX-WDC2 or SPX-WDC3
(Refer to Table 1)
Window
Close: ON
Open: OFF
Card key unit
Insert Card: ON
Remove Card: OFF
Window
Close: ON
Open: OFF
Window
Close: OFF
Open: ON
Connection
Window
Close: OFF
Open: ON
OPTION LIST
AIR CONDITIONER INDOOR PCB
CN6 or CN9
(Refer to Table 1)
DIP SW Label
(Refer to Table 1)
Card key unit
Insert Card: OFF
Remove Card: ON
10-13