Model Designation; Specifications; Plug Configurations; Electrical Rating Chart-3Cs2 Models - Hatco HYDRO-HEATER 3CS2 Series Installation And Operating Manual

Sanitizing sink heaters, bain-marie heaters/food rethermalizers
Table of Contents

Advertisement

3CS = Three Compartment Sink
FR = Food Rethermalizer/

Plug Configurations

Some units are supplied from the factory with an electrical cord
and plug installed. Plugs are supplied according to the
applications.
WARNING
ELECTRIC SHOCK HAzARD: For units with an electrical
cord and plug, plug unit into a properly grounded electrical
receptacle of the correct voltage, size, and plug
configuration. If plug and receptacle do not match, contact
a qualified electrician to determine and install proper
voltage and size electrical receptacle.
Electrical Rating Chart—3CS2 Models
Model
Voltage
3CS2-3
208
240
3CS2-4
208
240
3CS2-6
208
240
3CS2-3B
208
240
3CS2-4B
208
240
3CS2-6B
208
240
3CS2-9B
208
240
* Wire size is based on THHN copper wire for branch circuit protection at 0.91 derate factor. Circuit breakers and fused disconnects
are to be mounted remotely and wired by contractor. Sizes are based on the 2002 NEC table 310-16. Conduit size based on
conductors plus ground wire sizing per Table C1 from Appendix C.
† Based upon THHN wire rated 90ºC.
NOTE: Shipping Weight includes packaging.
Form No. HHM-0517
3 C S 2 - X B
Bain-Marie Heater
Hydro-Heater

Model Designation

Kilowatts
(kW)
Phase
3.0
1
3.0
1
4.0
1
4.0
1
6.0
1
6.0
1
3.0
3 (Bal.)
3.0
3 (Bal.)
4.5
3 (Bal.)
4.5
3 (Bal.)
6.0
3 (Bal.)
6.0
3 (Bal.)
9.0
3 (Bal.)
9.0
3 (Bal.)
Balanced—3 Phase
Kilowatt Rating
NEMA 6-20P
(Available for FR2-3 only)
NOTE: The specification label is located on the lower right side
toward the front of the unit. See label for serial number
and verification of unit electrical information.
Wiring Sizing
Amps
AWG*†
14.4
12
12.5
12
19.2
10
16.7
10
28.8
8
25
8
8.4
14
7.3
14
11.2
14
9.6
14
16.7
12
14.5
12
25
10
21.7
10
5
MODEL DESIGNATION

SPECIFICATIONS

NEMA 6-30P
(Available for FR-4 only)
Plug Configurations
Fuse or
Circuit Breaker* Shipping Weight
20
24 lbs. (11 kg)
20
24 lbs. (11 kg)
30
24 lbs. (11 kg)
30
24 lbs. (11 kg)
40
27 lbs. (12 kg)
40
27 lbs. (12 kg)
15
24 lbs. (11 kg)
15
24 lbs. (11 kg)
20
24 lbs. (11 kg)
15
24 lbs. (11 kg)
30
27 lbs. (12 kg)
20
27 lbs. (12 kg)
40
27 lbs. (12 kg)
30
27 lbs. (12 kg)

Hide quick links:

Advertisement

Table of Contents
loading