Troubleshooting; Warranty - Project Source F1A1F506CP Manual

Tub and shower faucet
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

PROBLEM
Hot and cold are reversed. Lines reversed or cartridge
There is no or a low water
flow.
There is leaking or dripping
from the spout after turned
off the handle.
There is only hot water or
only cold water from the
spouts.
Water comes out of the
tub spout and showerhead
at the same time when
turning on.

WARRANTY

The manufacturer warrants this faucet to be free from defects in workmanship and material present
at time of shipment from the factory for a limited lifetime from the date of purchase. This warranty
applies only to the original purchaser. The manufacturer agrees to correct such defects at no charge
or, at our option, replace the faucet with a comparable or superior model. To obtain warranty service,
call our customer service department at 1-866-389-8827 for return authorization and shipping
instructions. You may be required to present a copy of your sales receipt as proof of purchase. All
cost of removal and reinstallation are the expressed responsibility of the purchaser. Any damage to
the faucet by accident, misuse or improper installation, or by affixing accessories not produced by
the manufacturer, are the purchaser's responsibility. The manufacturer assumes no responsibility
whatsoever for faucet installation during the warranty period. There is no further expressed
warranty. The manufacturer disclaims any and all implied warranties. The manufacturer shall not
be liable for incidental, consequential or special damages arising at or in connection with product
use or performance except as may otherwise be accorded by law. This warranty gives you specific
legal rights, and you may also have other rights that vary from province to province. This warranty
supersedes all prior warranties.
POSSIBLE CAUSE
installed upside down.
One or both water supplies are
not turned on.
Grommets not sealing properly.
Misplacement of temperature
limit stops.
Balancing spool stuck.
If the pattern of the water flow
switches to the shower from the
tub spout, and the leak from the
tub spout is less than 0.01 GPM,
this is a normal occurrence. Or
consider the causes below:
The valve is installed upside
down.
The pipe used between the
valve and the tub spout is not
1/2 in. IPS, or the COPPER pipe
is incorrect.
The distance between the valve
and the showerhead is less than
49 in.
There is a restriction between
the valve and the tub spout.
CORRECTIVE ACTION
Rotate the cartridge stem 180° so
that the notch is facing down towards
the drain.
Turn both water supply valves
counterclockwise to the on position.
Replace the cartridge.
Reinstall the temperature limit stops
over the cartridge stem when the
round pit on the stem faces upward.
Replace the cartridge.
Change the pipe to 1/2 in. IPS or
COPPER.
Relocate the showerhead or valve to
ensure the minimal distance of 49 in.
Remove the tub spout and flush out
debris and/or replace the undersized
line or fittings.
Remove the valve and reinstall in the
proper orientation.
16

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F1A1F506CP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

F1a1f506np803750978037515008778120877813

Table of Contents

Save PDF