FX / RVE
Functioning
5.2.d - Head lifting (For models being equipped with)
(Fig.3)
DANGER
The head (1) shall be lifted when the machine does
not function and the cutout switch placed at the
upper part of the machine is off.
The machine is equipped with a safety microswitch,
which stops the machine functioning in case of a
lifting of the head.
• Loosen both knobs (2) placed on both structure sides,
until the head (1) is released.
• Lift the head (1), completely; the head position is kept
by the hydraulic absorber (3).
• To lower the head, make sure the coupling between
the head joint (4) and the motor joint (5) is correct, if
it is not the case, manually rotate the spiral element
(6) to allow the two joints to fit together.
• Tighten the knobs (2) to fix the head.
5.3 - MALFUNCTIONING, CAUSES AND RE-
MEDIES
- The machine doesnʼt start:
• check the electric connection.
• make sure that no foreign bodies are inside the
machine and stop the rotation.
• make sure the timer knob is on "TIMER" or on the
minute counter position.
• make sure both grid and head are properly lowered
and the head fixing knobs are tightened.