DIRECTIVE 2014/34/EU (ATEX)

Hazardous area
Gas
0
1
2
Equipment category
Category
1
2
3
Equipment group
Hazard
Gas
Dust
Temperature class
The equipment must be chosen so that its surface temperature does not exceed the ignition tem-
perature of the explosive gas present. Below are some examples of flammable gases classification
according to their ignition temperature (this list is not exhaustive).
Gas group
IIA
IIB
www.dalemans.com
Dust
Area
20
Continuous, long-term or frequent presence of explosive atmosphere.
21
Explosive atmosphere is likely to occur under regular operation.
Explosive atmosphere is not likely to occur under regular operation or, if
22
it does occur, it will only be for short-period.
Definition
Equipment with a "very high" degree of safety
Equipment with a "high" degree of safety
Equipment with a "normal" degree of safety
Group
Example
I
Methane
IIA
Propane
IIB
Ethylene
IIC
Hydrogen
IIIA
Combustible flyings
IIIB
Non-conductive dust
IIIC
Conductive dust
Temperature class and maximum surface temperature of the equipment
T1
450 °C
300 °C
Butane
Methane
Ethanol
Toluene
Methanol
Xylene
Propanol
Propane
IIC
City gas
Ethylene oxide
Hydrogen
Acetylene
T2
T3
200 °C
Kerosene
Nonane
Acetaldehyde
Octane
Pentane
Suitable for use in Zone
0 and 20
1 and 21
2 and 22
Equipment
Intended for use in mines
Intended for use in other locations than
mines
T4
T5
135 °C
100 °C
Ethyl ether
T6
85 °C
Carbon
disulphide
|
5