Communication Test - Aeotec 7 Pro ZWA012 User Manual

Door / window sensor
Table of Contents

Advertisement

Aeotec Door/Windows Sensor 7 Pro User guide : Aeotec Help Desk
Refer to section "Parameter Configurations"
Parameter 1 will determine what mode the Door / Window Sensor 7 is used as.

Communication test.

This utilizes the Power Level command class to determine the health between the Door / Window Sensor 7 and your
Z-Wave gateway. This will tell you if the Door / Window Sensor 7 has a healthy connection to your system and is a great
method of debugging connectivity issues.
1.
Set Parameter #5 to value #1
2.
Double click the Tamper Switch.
3.
Result:
Blinks once - success
Blinks 3x times - failure
Scene Controller.
When activated by configuration parameter #14 the device can perform as a scene controller. The external dry contact will
then act as a scene controller with a total of 7 scenes that can be activated:
1.
Contact Pressed 1 time
2.
Contact Pressed 2 time
3.
Contact Pressed 3 time
4.
Contact Pressed 4 time
5.
Contact Pressed 5 time
6.
Contact held down
7.
Contact released
Firmware-Update over the Air.
This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central
controller. Once the controller starts the update process, perform the following action to confirm the firmware update:
1.
Wake Up the device by removing the cover.
2.
The hit the tamper switch once.
Send a wake-up notification.
In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be
woken up.
1.
Wake Up the device by removing the cover.
2.
The hit the tamper switch once, led blinks short green.
Note: Door / Window Sensor 7 Pro remains awake until the housing is closed again.