HomeServer 3 - Commissioning

2.4 Functions test and commissioning

To put the HomeServer into operation, two basic topics must be considered:
– installing and connecting the HomeServer
– functions test and commissioning
In this chapter you will learn how to carry out a functions test and how to put the Home-
Server into operation.
Attention: Commissioning must only be carried out by skilled electricians!
The connection and commissioning of the HomeServer may only be carried out by elec-
trical personnel who have been trained for this purpose.

2.4.1 Functions test via internet browser

The HomeServer is already equipped with a sample project on delivery. Three users are
created in this sample project. You can log into the HomeServer using their login data.
The user interface is designed for use at a monitor resolution of 1024 x 768. The project
has been designed for access via the local network. Access via the internet is not planned
but can be quickly setup if required.
The following users are stored in the sample project:
User name
Password in browser or in the client program
admin
admin
u1
u1
u2
u2
u3
u3
All users stored in the sample project have administrator rights. Via the user interface, you
can access a visualization, a user menu (timer, calendar of public holidays, calendar of
holidays, message list, diagram of measured values) and some lists from within the inter-
net browser or client program.