RH-53/54
8-System Module
■
DC Characteristics
Supply Voltage Ranges
Signal
Battery Voltage
Flashing Voltage
Charger Input Voltage
Following voltages are assumed as normal and extreme voltages for used battery:
Source
VBAT
3.21V
Vcoff+
3.0V
Vcoff-
2.7V
Vmstr+
2.0V
Vmstr-
1.8V
Sw shutdown
-
1 TA will test with the nominal voltage at an 85% range (0.85 x 3.7V = 3.145V); therefore the
nominal voltage has been set to 3.8V. ADC settings in the SW might shutdown the phone
above the min value. During fast charging of an empty battery, the max voltage might exceed
this value. Voltages between 4.20 and 4.60 might appear for a short while.
ISSUE 1 09/2004
Table 2: Supply voltage ranges
Table 3: Battery voltages
Min
Nom
3.80V
3.1
2.8V
2.1V
1.9V
3.1V
COMPANY CONFIDENTIAL
Copyright © 2004 Nokia. All Rights Reserved.
Nokia Customer Care
Rating
0 ... 4.39V (VBAT)
0 ... 5.15V
-0.3 ... 9.2VRMS (16,9 Vpeak)
Max
4.39V
3.2
2.9V
2.2V
2.0V
-
Note
1
HW off to on
HW on to off
HW off to on
HW on to off
In Call
15