Fig 32 Uhf Vco Signal Level And Frequency - Nokia RH-13 Series Troubleshooting Manual

Transceivers
Table of Contents

Advertisement

RH-13
Troubleshooting
6 Connect spectrum analyzer probe to the UHF VCO output and record signal level
and frequency. Signal level should be around -5 dBm and frequency 2093.2 MHz.
The result should be like in the picture below:
7 Repeat measurement for channels 512 and 810.
Page 50
Output
G802
Figure 32: UHF VCO signal level and frequency