Weinmann SOMNObutler 2 stationary Description And Instructions For Use

Advertisement

Quick Links

SOMNObutler 2
Storage system
SOMNObutler 2 stationary
SOMNObutler 2 mobile
Description and Instructions for use
WM 95358
WM 95359

Advertisement

Table of Contents
loading

Summary of Contents for Weinmann SOMNObutler 2 stationary

  • Page 1 SOMNObutler 2 Storage system SOMNObutler 2 stationary WM 95358 SOMNObutler 2 mobile WM 95359 Description and Instructions for use...
  • Page 2 The pulsoximetry sensor can be pushed onto this 9 Spring bracket. The spring keeps the Transferbox 2 in its bracket. 5 Bracket for diagnosis device The WEINMANN diagnosis device can be hung from this bracket. Overview...
  • Page 3 Wall mounting for Catch for wall mounting SOMNObutler 2 stationary 5 Control pin 1 Catch 2 Bore 3 Guide pin 7 Catch cross- 6 Catch housing 4 Bottom rail 1 Catch 5 Control pin 2 Bore 6 Catch housing 3 Guide pin...
  • Page 4 2 Lug for carrying strap 7 Bracket for diagnosis device The carrying strap for the storage system can be The WEINMANN diagnosis device can be hung attached to this lug. from this bracket. 3 Device platform 8 Bracket for abdominal strap...
  • Page 5 11 Push-button 13 Knurled screw The push-buttons are used to fix the protective The knurled screw is for fixing the hanger in bag to the storage system. position. 12 Hanger The hanger is for hanging the storage system from a hospital bed or standard hospital rail. Scope of supply and accessories for SOMNObutler 2 mobile Protective bag Flap of bag...
  • Page 6 Rear view of SOMNObutler 2 1 Angle piece for USB/PC galvanic isolation 3 Vibration dampers module 4 Hinge for bottom rail 2 Adjustable screw to fix the angle piece in 5 Space for storing cables position Overview...
  • Page 7 Special markings on the device Storage system Wall mounting Markings on the storage system Symbol Significance Storage system information plate Year of manufacture Serial number of storage system CE symbol (confirms that the product conforms to applicable European directives) Storage system Do not dispose of the storage system in domestic waste.
  • Page 8 Safety instructions Safety instructions indicate information relevant to safety. Within instructions for use, you will find safety instructions in front of a step which contains a hazard to persons or objects. Safety instructions consist of – the warning symbol (pictogram) –...
  • Page 9: Table Of Contents

    Attach accessories bag ..22 Operate the SOMNObutler 2 stationary ..23 Remove devices ....23 After use .
  • Page 10: Description Of Device

    SOMNObutler 2 is a storage system to enable the components and accessories of a WEINMANN polysomnography system required by the patient to be stored and/or transported. In addition to the bracket for the WEINMANN diagnosis device, the storage system also provides brackets and storage space for the Transferbox 2, the USB/PC galvanic isolation module, master cable, straps, pulsoximetry sensors and electrodes, for example.
  • Page 11: Safety Instructions

    2. Safety instructions Read these instructions for use carefully. They form part of the storage system and must be available at all times. Only use the storage system for the purpose described (see “1.1 Intended purpose” on page 10). For your own safety and the safety of your patients and in accordance with the requirements of Directive 93/42/EEC, please note the following.
  • Page 12: Accessories/Replacement Parts

    Please note that in these cases, any claim under warranty and liability will be invalidated if neither the accessories nor genuine replacement parts recommended in the instructions for use are used. 2.4 Maintenance Caution! Have servicing and maintenance work carried out only by the manufacturer, WEINMANN or by trained staff. Safety instructions...
  • Page 13: Fit Somnobutler 2 Stationary

    3. Fit SOMNObutler 2 stationary 3.1 Fit wall mounting The SOMNObutler 2 stationary storage system can be hung in the BASE STATION 3 NG wall mounting for SOMNObutler 2, WM 95347. For instructions on fitting the wall mounting to the wall, see the assembly instructions for BASE STATION 3 NG for SOMNObutler 2 WM 96667 enclosed with the wall mounting.
  • Page 14: Connect Diagnosis Device

    3. Pass the charging/data transfer cable forwards through the bottom opening in the device platform. 4. Connect the charging/data transfer cable to the connection for the charging/data transfer cable of the diagnosis device. Fit SOMNObutler 2 stationary...
  • Page 15: Connect Transferbox 2

    8. Pass the power cord of the Transferbox 2 forwards between the device platform and the rear wall. 9. Connect the power cord to the power supply connection of the Transferbox 2. 10.Connect the power supply unit to the power supply. Fit SOMNObutler 2 stationary...
  • Page 16: Fit Shelf

    1. Connect the USB/PC galvanic isolation module (see “3.3 Connect USB/PC galvanic isolation module” on page 13). 2. Hold the storage system by both protective hoops and lift it up. 3. Insert the storage system in the bottom rail. Bottom rail Fit SOMNObutler 2 stationary...
  • Page 17 – Ensure that the red control pin is flush with the top edge of the catch housing and does not protrude. 4. Swivel the storage system towards the wall until you hear and see the catch cross-bar engage in the storage system. Fit SOMNObutler 2 stationary...
  • Page 18: Fit Somnobutler 2 Mobile

    4. Fit SOMNObutler 2 mobile 4.1 Remove protective bag 1. Place the storage system on a firm, level surface. 2. Open the clips on the protective bag. 3. Release the Velcro tabs around the protective hoops. 4. Open the push-buttons on top of the storage system. 5.
  • Page 19: Connect Usb/Pc Galvanic

    4.3 Connect USB/PC galvanic isolation module 1. Turn over the storage system. 2. Push the USB/PC galvanic isolation module through one of the two large openings between the device platform and the rear wall of the storage system. 3. Push the USB/PC galvanic isolation module between the padded angle piece and the padded top of the storage system.
  • Page 20: Connect Diagnosis Device

    4.4 Connect diagnosis device 1. Connect the charging/data transfer cable of the diagnosis device to the USB/PC galvanic isolation module. 2. Stow the charging/data transfer cable between the device platform and the rear wall of the storage system. 3. Pass the charging/data transfer cable forwards through the bottom opening in the device platform.
  • Page 21: Attach Protective Bag

    6. Pass the Ethernet cable of the Transferbox 2 forwards between the device platform and the rear wall. 7. Connect the Ethernet cable to the PC connection of the Transferbox 2. 8. Connect the Ethernet cable of the Transferbox 2 to your network socket.
  • Page 22: Attach Carrying Strap

    4.7 Attach carrying strap 1. Pass the fixing loops through the lugs for the carrying Lug for strap on the storage system. carrying 2. Close the Velcro tabs of the fixing loops. strap 3. Close the clips on the carrying strap. 4.8 Attach accessories bag 1.
  • Page 23: Operate The Somnobutler 2 Stationary

    2. Hang the diagnosis device from the bracket for the diagnosis device. 3. Connect the charging/data transfer cable to the diagnosis device. 4. Hang the electrodes at the sides of the shelf. 5. Place loose cables and other small parts on the shelf. Operate the SOMNObutler 2 stationary...
  • Page 24: Remove Shelf

    7. Push the pulsoximetry sensor onto the bracket for the pulsoximetry sensor. 8. Attach the master cable to the bracket for the master cable. 5.3 Remove shelf 1. Release the push-buttons between the shelf and the storage system. 2. Remove the shelf. Operate the SOMNObutler 2 stationary...
  • Page 25: Remove Storage System From Wall Mounting

    – Hold the storage system steady by one of the protective hoops when unlatching it. 1. Remove the shelf. 2. To unlatch, pull the catch cross-bar upwards. 3. Swivel the storage system slightly forwards. 4. Remove the storage system upwards off the bottom rail. Operate the SOMNObutler 2 stationary...
  • Page 26: Operate The Somnobutler 2 Mobile

    6. Operate the SOMNObutler 2 mobile For information on how to operate the individual components of the polysomnography system, see the instructions for use for the components in question. Caution! Risk of injury from storage system tilting or falling down! A tilting or falling storage system can injure people and cause material damage.
  • Page 27: Remove Devices

    6.1 Remove devices 1. Disconnect all cables, sensors, straps and electrodes from the diagnosis device and the Transferbox 2. 2. Press the spring above Transferbox 2 into the device platform. 3. Pull the Transferbox 2 up out of its bracket. 4.
  • Page 28: Use Of Organizer Boxes

    6.3 Use of organizer boxes 1. Stow cables, electrodes, sensors and other small parts in the two organizer boxes. 2. Open the clips on the protective bag. 3. Open the flap of the inside pocket. 4. Push the two organizer boxes into the inside pocket. 5.
  • Page 29: Hang Storage System From Standard Hospital Rail

    6.5 Hang storage system from standard hospital rail Caution! Risk of injury from additional load! Extra weight, e.g. from supporting a person, when the system is attached can cause the storage system to fall off. – Do not lean on the storage system. –...
  • Page 30: Hygiene Treatment

    7. Hygiene treatment Always perform a function check following hygiene treatment (see “8. Function check” on page 32). 7.1 SOMNObutler 2 stationary Clean storage system 1. Take the devices off the storage system. 2. Wipe down the storage system with a slightly damp cloth and mild detergent.
  • Page 31 Clean protective bag, accessories bag and carrying strap 1. Take the carrying strap, protective bag (see “4.1 Remove protective bag” on page 18) and accessories bag off the storage system. 2. Wash the bags and the carrying strap in a washing machine. Choose a 30 ˚C washing cycle without a spin.
  • Page 32: Function Check

    If you discover faults during the function check, do not use the storage system again until the faults have been rectified. 8.2 SOMNObutler 2 stationary Visual inspection 1. Look at the storage system closely. The storage system may not be damaged in any way –...
  • Page 33: Somnobutler 2 Mobile

    2. Check unlatching. Hold the storage system firmly and pull the catch cross-bar upwards. – The catch cross-bar must be easy to move. – The storage system may not catch on removal. 8.3 SOMNObutler 2 mobile Visual inspection 1. Look at the storage system closely. The storage system may not be damaged in any way –...
  • Page 34: Servicing

    Look these up in the associated instructions for use if appropriate. We recommend having maintenance measures such as servicing and repair work carried out by the manufacturer, WEINMANN, or by specialist staff. 9.1 Disposal Storage systems and wall mounting Do not dispose of the device in domestic waste.
  • Page 35: Scope Of Supply

    10. Scope of supply 10.1 Standard scope of supply SOMNObutler 2 stationary WM 95358 Description Order no. SOMNObutler 2 basic device WM 95330 Wall mounting BASE STATION 3 NG for SOMNObutler 2 WM 95347 Shelf, SOMNObutler 2 WM 95352 Instructions for use for SOMNObutler 2 GB...
  • Page 36: Accessories

    WM 95362 – bracket for Transferbox 2 – bracket for diagnosis device – bracket for pulsoximetry sensor (2x) 10.3 Replacement parts SOMNObutler 2 stationary Description Order no. Wall mounting BASE STATION 3 NG for SOMNObutler 2 WM 95347 Shelf, SOMNObutler 2...
  • Page 37 SOMNObutler 2 mobile Description Order no. Carrying strap with fixing loops WM 8298 Organizer box (2x) WM 95361 Protective bag SOMNObutler 2 WM 95329 Set, spring for SOMNObutler 2 consisting of: WM 95357 – spring – countersunk bolt (2x) – washer (2x) –...
  • Page 38: Technical Data

    Directive 93/42/EEC Dimensions 465 x 295 x 145 W x H x D in mm SOMNObutler 2 stationary excluding wall mounting: 4.5 kg Weight SOMNObutler 2 stationary including wall mounting: 6.1 kg SOMNObutler 2 mobile including protective bag: 6.1 kg Temperature range –...
  • Page 39: Warranty

    – Failure to use original spare parts. • WEINMANN is not liable for consequential harm caused by a defect if it is not based on intention or gross negligence. WEINMANN is also not li- able for minor physical injury to life or limb resulting from negligence.
  • Page 40: Declaration Of Conformity

    13. Declaration of conformity WEINMANN Geräte für Medizin GmbH + Co. KG declares herewith that the product com- plies fully with the respective regulations of the Medical Device Directive 93/42/EEC. The unabridged text of the Declaration of Conformity can be found on our website at: www.weinmann.de...
  • Page 44 WEINMANN Geräte für Medizin GmbH+Co.KG P.O.Box 540268 • D-22502 Hamburg Kronsaalsweg 40 • D-22525 Hamburg T: +49-(0)40-5 47 02-0 F: +49-(0)40-5 47 02-461 E: info@weinmann.de www.weinmann.de Center for Production, Logistics, Service WEINMANN Geräte für Medizin GmbH+Co.KG Siebenstücken 14 D-24558 Henstedt-Ulzburg...

This manual is also suitable for:

Somnobutler 2 mobileWm 95358Wm 95359

Table of Contents