Troubleshooting

12 Troubleshooting
You can rectify minor faults on your appliance yourself. Read the troubleshoot-
Troubleshooting
ing information before contacting after-sales service. This will avoid unneces-
sary costs.
WARNING
Risk of electric shock!
Incorrect repairs are dangerous.
Repairs to the appliance should only be carried out by trained specialist
staff.
Only use genuine spare parts when repairing the appliance.
If the power cord of this appliance is damaged, it must be replaced by the
manufacturer, the manufacturer's Customer Service or a similarly qualified
person in order to prevent any risk.
Fault
The LED lighting does
not work.
The base of the refri-
gerator compartment
is wet.
The temperature dif-
fers greatly from the
setting.
Cause and troubleshooting
The illuminant is defective.
Switch off the appliance. → Page 31
1.
Disconnect the appliance from the mains.
2.
Unplug the appliance from the mains or switch off
the circuit breaker in the fuse box.
Slide the illuminant cover backwards
3.
the illuminant cover to the left
→ Fig.
8
Replace the illuminant.
4.
Replacement illuminant: 220–240 V AC, E14 bulb
holder, see the defective illuminant's wattage.
The light switch is jammed.
Check whether the light switch can be moved.
→ Fig.
9
The condensation channel or drainage hole are
blocked.
Clean the condensation channel and the drainage
hole. → Page 34
Different causes are possible.
Switch off the appliance. → Page 31
1.
Switch the appliance back on after five minutes.
2.
→ Page 31
If the temperature is too warm, check the temper-
ature again after a couple of hours.
If the temperature is too cold, check the temper-
ature again on the following day.
Troubleshooting en