Overview Configuration Parameters - Abus Nexello PLBW10000 Manual

Dual motion detector
Hide thumbs Also See for Nexello PLBW10000:
Table of Contents

Advertisement

3.4. Overview configuration parameters

Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behaviour of the device even better to the requirements of the application and
to activate additional functions.
Use your Z-Wave controller to initiate the changes to the parameters. In order for the device to receive
the values, a wake-up must be performed on the device itself. (see point 2.5)
Param
Byte
eter
size
Temperature & Humidity
1
2
Waiting time between
2
2
two motion alarms
Reset waiting time after
3
2
(Association Group 2)
Temperature report
4
1
Air humidity report
5
1
6
1
Function
Report
(Time)
motion alarm
(threshold)
(threshold)
LED status
(motion alarm)
Default
Description
value
The interval time of the temperature and
humidity report.
30
Adjustable from 1 - 1440 in minutes
(Hexadecimal: 0x01 - 0x5A0)
Waiting time from one motion alarm to the next
triggering.
160
Adjustable from 10 - 3600 in seconds
(Hexadecimal: 0x10 - 0xE10)
Waiting time after a movement alarm until
reset. Additionally, defines how long directly
associated devices from group 2 are activated.
180
Adjustable from 10 - 3600 in seconds
(Hexadecimal: 0x10 - 0xE10)
Additional temperature report, which is sent
when the set threshold is exceeded.
The value 0 deactivates the temperature report.
5
Adjustable from 0 - 10 in 0.5° steps
(e.g. 5 = 2.5°)
(Hexadecimal: 0x00 - 0x0A)
Additional humidity report that is sent when the
set threshold is exceeded.
A value of 0 disables the humidity report.
5
Adjustable from 0 - 10 in 5% steps
(e.g. 5 = 25%)
(Hexadecimal: 0x00 - 0x0A)
Set whether the status LED lights up in case of
a motion alarm.
1
0 = LED deactivated
1 = LED activated
(Hexadecimal: 0x00 - 0x01)
16
English

Advertisement

Table of Contents
loading

Table of Contents