03. DISABLE DIRECT HAZARDS / SAFETY REGULATION
3. Locate the 12V battery's charging points and
disconnect the 12V negative cable.
If the 12V battery is to be disconnected complete-
ly, the ground/minus pole must be disconnect-
ed, otherwise there is a risk of short circuits. The
negative pole must be protected against renewed
contact (insulation, tying away, bending away). If
the battery is disconnected, it should be checked
whether the vehicle is actually voltage-free. The
extinguishing of the hazard warning lights or the
interior lighting can serve as a sign.
High voltage Manual service dis-
connect
The XC40 Recharge Pure Electric
have a manual high voltage service
disconnect plug.
The high voltage service disconnect
plug is located in front of the right
rear passenger under a flap that must be opened.
The orange rubber protective cap underneath the
flap must be removed. Please see the location
below.
Disconnect the high voltage service plug
This operation also disconnects the traction battery
from the rest of the system.
1. Pull the lever to the rear.
2. Turn lever upwards and pull out plug in upward
direction.