Metering Unit - Stihl SR 5600 Instruction Manual

Hide thumbs Also See for SR 5600:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3

Metering Unit

Stop Cock
1
Stock cock (1) at right angle to
N
control handle = closed
Stock cock (1) parallel to control
N
handle = open
Adjust the discharge rate with the
N
metering knob – not the stop cock.
SR 5600
Metering Knob
2
4
3
The discharge rate can be infinitely
N
varied by turning the metering
knob (2) on the nozzle (3).
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (4) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Spray tube angle
Knob setting
- 30°
1
0,28
0,28
2
0,92
0,85
3
2,22
1,73
4
2,96
2,36
5
3,41
2,7
6
3,62
2,91
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Spray tube angle
Knob setting
- 30°
0,5
0,1
0,09
0,65
0,12
0,12
0,8
0,16
0,15
Discharge rate (l/min) with pressure
pump (special accessory)
Spray tube angle
Knob setting
- 30°
1,0
0,75
0,74
1,6
2,12
2,02
2,0
3,15
3,09
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Spray tube angle
Knob setting
- 30°
0,5
0,19
0,18
0,65
0,29
0,28
0,8
0,48
0,47
English
+ 30°
0,2
0,79
1,33
1,75
2,03
2,19
+ 30°
0,08
0,1
0,14
+ 30°
0,74
1,98
3,06
+ 30°
0,18
0,27
0,47
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents