5.9.4
Free in the market available flue gas materials (C63).
The properties of the combustion determine the choices for the flue material.
The standards EN 1443 and EN 1856-1 provide the necessary information for choosing the
flow material by means of a sticker including an identification string.
The Identification string contains the following information:
A
CE marking
B
The standard to comply to:
The ID string needs to contain the following information:
C
Temperature class
D
Pressure class
E
Resistance class
F
Resistance class in case of fire
Dimensions C63 Flue system (external dimensions in mm)
Parallel
Concentric 80/125
Flue pipe
+0,3
+0,3
ø 80
ø 80
- 0,7
- 0,7
Flue materials of different markings must not be combined !
Metal,
EN 1856-2
Plastic,
EN 14471
: T120
: Pressure (P) or High Pressure (Hi)
: W (Wet)
: E
Concentric 60/100
Air inlet
Flue pipe
+ 2
+0,3
ø 125
ø 60
- 0
- 0,7
Air inlet
+ 2
ø 100
- 0
28