Startup And Shutdown Opera�On; How To Use The Touch Screen - Viking Magni 2500 User Manual

Table of Contents

Advertisement

Available languages

Available languages

Startup and shutdown opera�on
(1) Start up: short press the power bu�on, the indicator light is on, and the machine is
in standby mode.
(2) Shutdown: press and hold the power bu�on for more than 2 seconds, and the indi-
cator light will be off and the machine shut off.
BMS Over current or short circuit
protec�on
BMS Startup �meout
Normal startup
Normal shutdown
(3) DC power switch and AC power switch are integrated in the interac�on LCD
screen(Figure 1),press"DC ON/OFF"bu�on and "AC ON/OFF"bu�on on the screen to
turn on/off the DC /AC output.

How to use the touch screen

Interac�on LCD screen(Informa�on Vision) supports below func�ons:
(1) Real �me display of voltage, current, power, temperature and state of charge and
discharge.
(2) The user can adjust the output voltage, frequency, charging mode, power consump�on
mode and �me informa�on according to the se�ng column.
(3) Support energy-saving, and enable Super ECO mode to save more than 30% of
useless energy loss.
(4) Support users to view fault informa�on, historical fault informa�on, so�ware version
independently.
5. The opera�on steps of touch screen
Warm �p: ●The touchable LCD screen is a resistance screen. we recommend to press
the touch bu�on by fingernail lightly un�l it "beeps".
●In order to maximize the lifespan of the LCD screen, please avoid direct sunlight on it.
(1) When press the power bu�on,it will enter the main interface of the LCD display screen:
The LED indicator lamp status warning
Turn off a�er the indicator light flashes
The indicator light flashes and not shut down
The indicator light on
The indicator light off
4