Step 1 -- Setting The Unit - Lennox Merit Series Installation Instructions Manual

Table of Contents

Advertisement

UNIT DIMENSIONS - INCHES (MM)
A
SIDE VIEW
FIGURE 2
TABLE 1
UNIT DIMENSIONS
Model Numbers
14ACX-018-230
24-1/4 (616)
14ACX-024-230
28-1/4 (724)
14ACX-030-230
28-1/4 (724)
14ACX-036-230
28-1/4 (724)
14ACX-041-230
28-1/4 (724)
14ACX-042-230
28-1/4 (724)
14ACX-048-230
28-1/4 (724)
14ACX-059-230
32-1/4 (819)
14ACX-047-230,
32-1/4 (819)
14ACX-060-230

STEP 1 -- SETTING THE UNIT

(CONTINUED) -- Unit Placement
CAUTION
Before attempting to perform any service or mainte­
nance, turn the electrical power to unit OFF at disconnect
switch.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take care
while handling this equipment and wear gloves and pro­
tective clothing.
WARNING
To prevent personal injury, as well as damage to panels,
unit or structure, observe the following:
While installing or servicing this unit, carefully stow all
removed panels so that the panels will not cause injury
to personnel, objects or nearby structures. Also, take
care to store panels where they will not be subject to
damage (e.g., being bent or scratched).
While handling or stowing the panels, consider any
weather conditions (especially wind) that may cause
panels to be blown around and damaged.
B
A
B
29-1/4 (743)
29-1/4 (743)
37-1/4 (946)
37-1/4 (946)
37-1/4 (946)
33-1/4 (845)
37-1/4 (946)
37-1/4 (946)
33-1/4 (845)
Roof Damage!
This system contains both refrigerant and oil. Some
rubber roofing material may absorb oil, causing the
rubber to degrade. Failure to follow this notice could
result in damage to roof surface.
Exhaust vents from dryers, water heaters and fur­
naces should be directed away from the outdoor unit.
Prolonged exposure to exhaust gases and the chemi­
cals contained within them may cause condensation
to form on the steel cabinet and other metal compo­
nents of the outdoor unit. This will diminish unit per­
formance and longevity.
Install unit level or, if on a slope, maintain slope tolerance of 2
degrees (or 2 inches per 5 feet [50 mm per 1.5 m]) away from
building structure.
BUILDING
STRUCTURE
STEP 2 -- REFRIGERANT PIPING -- Flush­
ing Existing Line Set and Indoor Coil
Flush the existing line set per the following
instructions. For more information, refer to the
Installation and Service Procedures manual available
on LennoxPROS.com. CAUTION - DO NOT attempt to
flush and re-use existing line sets or indoor coil when
the system contains contaminants (i.e., compressor
burn out).
Page 2
NOTICE !
IMPORTANT !
PLACEMENT
INSTALL UNIT AWAY
FROM WINDOWS
TWO 90º ELBOWS INSTALLED IN LINE SET
WILL REDUCE LINE SET VIBRATION
FIGURE 3
SLAB MOUNTING
DISCHARGE AIR
MOUNTING SLAB
GROUND LEVEL
FIGURE 4
14ACX SERIES

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

14acx-018-23014acx-024-23014acx-030-23014acx-036-23014acx-041-23014acx-042-230 ... Show all

Table of Contents