INSTALLATION
• Permanently connected (Hard wired).
• Rated 240V, 60Hz, 50A, three wires (#6 copper) plus ground (#8 copper (8.42mm
total].
• Circuit breaker or fuse size: 50A.
• A disconnecting means must be installed within sight from the equipment and at least 5 feet
(1.52m) from the inside walls of the spa.
• Connect only to a circuit protected by a Class A ground Fault Circuit Interrupter (GFCI).
Red (hot) wire connected to #2 on terminal block.
Black (hot) wire connected to #3 on terminal block.
White (neutral) wire connected to #4 on terminal block.
Green (ground) wire routed through plastic enclosure and secured to exterior bonding lug.
Improperly wired spas are beyond Marquis Corp. control and are not covered under the warranty.
Other items beyond Marquis Corp. control include, but are not limited to, damage resulting from:
improper connections; accidents; failure to follow procedures and instructions defined in the Marquis
printed
instructions; cleaning agents; and natural occurrences including but not limited to rodent
or insect infestation, mold, lightning and other acts of nature.