Test Setup 3 - Nokia 6265 Rf Description And Troubleshooting

Mobile terminals
Table of Contents

Advertisement

Nokia Customer Care

Test Setup 3

• After passing the self-test, setup the JBT-3, JBT-9 or a later version BT box.
• Key in the BT box's Device address into the Counterpart BT Device Address
window.
• Select Run BER Test to run the BER loopback test. The BER result is visible in the
BER Test Results window.
• Since this is a "go-no-go" testing, make sure the test-jig/coupler is setup
correctly. It is recommended to run couple "good" mobile terminals in order to
get better correlation. The acceptance criteria is BER<0.1%.
Issue 1 11/2005
©2005 Nokia Corporation
6265/6265i/6268 (RM-66)
RF Description and Troubleshooting
Company Confidential
Page 79