Balboa BP6013G1 Installation And Directions Of Use page 17

Advertisement

SIG (Configuration Signature)
Displays the checksum for the system configuration file.
Heater Voltage (Feature not used on CE rated systems.)
Displays the operating voltage configured for the heater.
Heater Wattage as Configured in Software (CE Systems Only.)
Displays a heater kilowatt rating as programmed into the control system software (1-3 or 3-6).
H _ (Heater Type)
Displays a heater type ID number.
SW _ (Dip Switch Settings)
Displays a number that represents the DIP switch positions of S1 on the main circuit board.
PANL (Panel Version)
Displays a number of the software in the topside control panel.
Additional Utilities
Utilities
In addition to INFO, The Utilities Menu contains the following:
GFCI (GFCI Test)
(Feature not available on CE rated systems.)
GFCI Test is not always enabled, so it may not appear. This screen allows the GFCI to be tested manually from the
panel and can be used to reset the automatic test feature. If the GFCI Test Feature is reset, the device will trip within
7 days.
A / B (A/B Sensor Temperatures)
When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in
the heater.
FALT LOG (Fault Log)
The Fault Log is a record of the last 24 faults that can be
reviewed by a service tech.
DEMO (Demo Mode)
Demo Mode is not always enabled, so it may not appear. This is designed to operate several devices in a sequence
in order to demonstrate the various features of a particular hot tub.