SPECIFICATION

Outdoor model
Function
Power supply
Capacity
Dehumidification
Air flow(High/ Low)
Power outlet
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Maximum current
Coefficient of performance(C.O.P)
Model
Output
Winding
resistance(at 20:)
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Sound level(High)
Fan speed(High)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil (Model)
NOTE: Test conditions are based on AZ/NZS 3823.1.1.
Cooling : Indoor
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature 24°C
Indoor-Outdoor piping length : 7.5m
Air inlet
(back and side)
Piping
Drainage hose
Air outlet
Drain outlet
kW
L/h
K /h
A
A
W
%
A
A
A
A
W
"
"
mm
kg
dB
rpm
kg
L
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
MU-GA60VB
MU-GA80VB
MU-GA50VB
Cooling
Single phase
230V, 50Hz
5.1
1.4
2,322/ –
15
7.69
1,681
95
37
7.14
0.55
11.5
2.91
RN196VHSHT
1,300
C-R 1.80
C-S 3.00
RA6V60-MA
WHT-BLK 71
BLK-RED 89
850o605o290
45
52
873
1
1.60
0.52(NEO22)
3
Air inlet
(back and side)
Air outlet
MU-GA60VB
Cooling
Single phase
230V, 50Hz
6.5
2.3
2,940/1,470
25
10.09
2,251
97
45 or less
9.52
0.57
15.0
2.80
NN25VBAHT
1,600
C-R 0.89
C-S 2.03
RA6V75-AD
WHT-BLK 62.8
BLK-YLW 55.9
YLW-RED 26.0
840o850o330
73
55/53
805/435
2
2.40
1.20(NEO22)