RM-750
General Information
Environmental conditions
Temperature conditions
Environmental condition
Normal operation
Reduced performance
Intermittent operation
No operation or storage
Charging allowed
Long term storage conditions
Humidity
Relative humidity range is 5...95%.
The HW module is not protected against water. Condensed or splashed water might cause malfunction. Any
submersion of the phone will cause permanent damage. Long-term high humidity, with condensation, will
cause permanent damage because of corrosion.
Vibration
The module should withstand the following vibrations:
• 5 - 10 Hz; +10dB / octave
• 10 - 50 Hz; 5.58 m
2
• 50 - 300 Hz; - 10 dB / octave
ESD strength
Conducted discharge is 8 kV (>10 discharges) and air contact 15 kV ( >10 discharges ).
The standard for electrostatic discharge is IEC 61000-4-2, and this device fulfils level 4 requirements.
RoHS
This device uses RoHS compliant components and lead-free soldering process.
Issue 1
Ambient temperature
o
-15
C...+55
o
-25
C...-15
o
+55
C...+70
o
-40
C...-15
o
+70
C...+85
o
<-40
C...>+85
o
-10
C...+60
o
0
C...+85
3
2
/ s
(0.0558 g
/ Hz)
COMPANY CONFIDENTIAL
Copyright © 2011 Nokia. All rights reserved.
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
Notes
Specifications fulfilled
Operational for shorts periods
only
Operation not guaranteed but an
attempt to operate does not
damage the phone.
No storage or operation: an
attempt may damage the phone.
BTemp measurement range for
charging.