Plume Management Installation; Installation Examples - Worcester Greenstar Condensfit II Installation Instructions Manual

Wall mounted gas condensing appliance flue 60/100 horizontal 1050mm fixed flue
Hide thumbs Also See for Greenstar Condensfit II:
Table of Contents

Advertisement

90° Elbows offset dimensions
The plume management kit run must be adequately supported to ensure
it does not separate.
▶ Use support brackets either side of the offset.
257mm
Fig. 44 90° elbows offset dimensions
45° Elbows offset dimensions
The plume management kit run must be adequately supported to ensure
it does not separate.
▶ Use support brackets either side of the offset.
157mm
Fig. 45 45° elbows offset dimensions
5.4

Plume management Installation

To ease assembly of the flue components, lightly grease the seals with
the solvent-free grease supplied.
▶ Check all the seals are properly seated in the grooves provided and
are in good condition.
▶ All flue joints must be sealed to prevent leakage of condensate and
flue products.
Horizontal plume management runs:
▶ The initial horizontal run from the terminal elbow must have a
minimum 10° fall back, (stop tabs in the elbow prevent less than 10°)
to the appliance for proper disposal of condensate.
▶ Any further horizontal runs after an elbow can be 3°.
Greenstar Condensfit II – 6 720 874 391 (2019/04)
NOTICE:
Damage to flue or terminal outlet.
Do not rotate the complete flue terminal assembly.
▶ The flue terminal outlet has built-in stops to limit rotation for
horizontal fluing. This prevents unwanted rain water from entering
the appliance. Do not attempt to force beyond the limit stops.
5.4.1
The plume extensions include a support clamp and are used to support
the plume management system at the joint connection point.
Each support clamp retains one length of Plume management extension.
183mm
When assembling multiple lengths of plume management, fully engage
the extension and then withdraw the tube approximately 10mm to allow
for expansion and contraction during operation and expansion due to
weather conditions.
Support clamp fitting
0010013713-001
Support clamp ( figure 46)
▶ Mark the position [1] for the wall clamp [2] so that it coincides with
the extension tube just below the top fitting (there are tabs [3] that
will position the clamp up against the top fitting). Allow for the 10mm
expansion gap on all joints.
▶ Drill a hole to suit the wall plug and fit the wall plug.
▶ Screw in the support clamp into the wall plug to the distance shown
in figure 46.
82mm
0010013712-001
Fig. 46 Support clamp fitting

Installation examples

1
65 mm
3
Plume management system
2
19