CONNECT WIRING

WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
1
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2
Connect house black to hood black wire, house white to
hood white wire, and house ground under Green Ground
Screw. Securely tighten cable clamp onto house wiring.

INSTALL HOOD

HOUSE
WIRING
(120 VAC)
1
Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
CARDBOARD
Keyholes. Tighten mounting screws securely. A long
(Use to protect
screwdriver works best.
cooktop)
2
Replace bottom cover.
3
Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
GREEN
GROUND
SCREW
4
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16,
40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!
5
Replace filters, turn on power at service panel, and test for
proper operation.
ALLURE
KEYHOLE (4)
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
®
QS3 SERIES
RANGE HOOD
Page 5
MOUNTING SCREW (4)
DUCT
TAPE
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)

Hide quick links: