C&D Technologies DCS Series Installation And Operation Procedures

Advertisement

Quick Links

RS02252
FOLLOW MANUFACTURER'S PUBLISHED INSTRUCTIONS
WHEN INSTALLING, CHARGING AND SERVICING BATTERIES
For additional information:
www.cdtechno.com
For Technical/Warranty Assistance, contact:
C&D Technologies, Inc.
200 Precision Drive, Suite 150
Horsham, PA 19044
+1 800-543-8630 or +1 717-553-7001
Fax +1 215-619-7899
Before handling cells or storing cell for future installation take time to read this manual. It contains
information that could avoid irreparable damage to the battery and/or void product warranty.

Advertisement

loading

Summary of Contents for C&D Technologies DCS Series

  • Page 1 RS02252 FOLLOW MANUFACTURER’S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES For additional information: www.cdtechno.com For Technical/Warranty Assistance, contact: C&D Technologies, Inc. 200 Precision Drive, Suite 150 Horsham, PA 19044 +1 800-543-8630 or +1 717-553-7001 Fax +1 215-619-7899 Before handling cells or storing cell for future installation take time to read this manual. It contains information that could avoid irreparable damage to the battery and/or void product warranty.
  • Page 2: Battery Description

    General: The purpose of this manual is to inform installers how to receive, install and maintain C&D Technologies® Deep Cycle Series (DCS) batteries for use in electric vehicle (EV) applications. Battery Description: The valve regulated lead acid (VRLA) battery is a minimal maintenance system utilizing an oxygen recombination cycle to minimize gassing and eliminate electrolyte maintenance.
  • Page 3: Receiving Instructions

    II. Receiving Instructions Upon receipt, inspect the batteries for physical damage to the containers and terminals. If found, a claim must be filed with the carrier within ten (10) days. Also check the packing slip to make sure all material has arrived. The batteries are shipped fully charged.
  • Page 4: Application Information

    VI. Application Information Each electrical vehicle design will have different charging parameters. The following are charging and environmental limits: Specification Minimum Typical Maximum Nominal Operating Voltage Range Functional Operating Voltage 7.2V 16.7V Recharge Varies** 104-108% 110% Operating Temperature – Normal -4°F (-20°C) 140°F (60°C) Operating Temperature –...
  • Page 5: Periodic Maintenance

    VII. Periodic Maintenance These VRLA batteries are maintenance free with respect to the electrolyte. However, the charging voltage, temperature, performance, and connection resistances must be monitored, and any necessary corrective actions taken if irregular values are observed to assure reliable standby power when required.