G-U BKS B-1993 Series Installation Instructions Manual page 39

Motor-driven shoot-bolt lock for narrow stile systems
Hide thumbs Also See for BKS B-1993 Series:
Table of Contents

Advertisement

Available languages

Available languages

y
y
If no errors occur during the test run, the red LED at the controller lights up and the signal
contact 1 "Locked by motor" closes.
If an error occurs, the controller outputs corresponding blink codes (see point 5.1).
Eliminate the displayed error and repeat the test run (see point 6.5).
y
y
Now remove the copper-coloured transport securing devices from the latch and
deadbolt triggers.
y
y
Then remove the service plug.
Keep the service plug and do not throw it away!
ISR 15
The service plug is required to activate the programming mode (see point 6).
y
y
The motor-driven shoot-bolt lock can now be used.
Fig.6: Test run successful
Fig.7: Removing the service plug
39