Restoring The Vt-Mspa2-2X To Factory Settings - Bosch Rexroth VT-MSPA2-2X/ A5/1A0/000 Manual

Valve amplifier for proportional valves without electrical position feedback
Table of Contents

Advertisement

26/36
Valve amplifier VT-MSPA2-2X | Commissioning
Parameters
Command value inversion
Inv
Function:
Digital (enable) input DI
DI
t
Z/B
G
S
DI
t
Z/B
G
S
Bosch Rexroth AG, Edition 04.2020, RE 30232-01-B
LED
Description
indicator
lamps
Command value inversion
DI
t
Z/B
G
S
Digital (enable) input
DI
t
Z/B
G
S
1) Ramp times effective only when 4Q operating mode is activated
2) The function of the digital input is XOR-linked to the internally selected state
8.6

RESTORING THE VT-MSPA2-2X TO FACTORY SETTINGS

This function is available exclusively directly upon switching on the operating
voltage. It resets all customer-specific parameters of the set valve to the factory
settings.
The module has to be de-energized.
1. Press and hold [Set] and switch on the supply voltage.
The LEDs signal the status shown on the left.
1. After some time, the LEDs switch to the status shown on the left.
The module is restored to factory settings.
2. Release [Set].
Restoring to factory settings is completed.
Editable
Output at test jack v
parameter
on/off
ON: +1 V
OFF: 0 V
1: Enable input
1 V
(default)
2: Inversion 2)
2 V
3: Ramp ON/OFF
3 V
2)
4: Simple ramp/
4 V
4Q ramp 2)