Gaggia Evolution XE Operating Instructions Manual page 38

Hide thumbs Also See for Evolution XE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
ENGLISH
8 -
PURIFIER REGENERATION
IMPORTANT : Regenerate the purifier at the intervals listed
below:
HARDNESS °F
8 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l.
From 21 to 30
regeneration after 850 l.
From 31 to 40
regeneration after 650 l.
From 41 to 60
regeneration after 450 l.
- place the empty 2 litre container under pipe E.
- shift levers C and D from left to right as shown in fig.8.2 and
remove the cover by loosening knob G, pour in 1.5 kg of sodium
chloride (coarse cooking salt) into the 8-litre purifier and 2 kg
into the 12-litre type.
- Replace the lid and shift lever from right to left as shown in
fig.8.3 and allow the salted water to drain out of pipe F until the
water is fresh.
- Shift lever D from right to left as shown in fig.8.4
A
WATER INLET
B
WATER OUTPUT
C
INLET TAP LEVER
D
OUTPUT TAP LEVER
E
DEPRESSURIZER PIPE
F
REGENERATION TUBE
G
COVER KNOB
12 LITRE PURIFIER
regeneration after 1600 l.
regeneration after 1250 l.
regeneration after 950 l.
regeneration after 650 l.
NB: These regeneration instructions are valid only provi-
ding the purifier is as that indicated in the figures. Should
it fail to correspond proceed as indicated in the instructions
attached to the purifier itself.
38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution xd

Table of Contents